Observational studyJournal of clinical monitoring and computing2026
Optic nerve sheath diameter as a real-time biomarker for epidural blood patch efficacy after post-dural puncture headache: a preliminary report.
Observational study in Journal of clinical monitoring and computing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Post-dural puncture headache (PDPH) following epidural anesthesia remains a frequent obstetric complication. While epidural blood patch (EBP) is the reference treatment, its efficacy assessment still relies on subjective pain reporting. This study explored whether changes in optic nerve sheath diameter (ONSD) measured by ultrasound could serve as an objective, real-time indicator of early EBP response. In this prospective, single-center observational study, 30 postpartum patients with PDPH undergoing EBP had ONSD measured before (H0) and 2 h after (H2) the procedure. Correlation between ΔONSD and ΔVAS pain scores was analyzed with bootstrap validation, and receiver operating characteristic (ROC) analysis identified thresholds associated with early response. Mean ΔONSD was 0.97 ± 0.55 mm, significantly correlated with pain reduction (r = - 0.64, p < 0.001; bootstrap 95% CI: -0.81 to - 0.36). ROC analysis showed good diagnostic performance (AUC = 0.96, 95% CI: 0.87-1.00), with a ΔONSD ≥ 0.40 mm threshold providing 100% sensitivity and 83% specificity for early improvement. These preliminary findings suggest that ONSD ultrasound may offer a feasible, noninvasive adjunct for assessing early EBP response in PDPH. The identified 0.40 mm change threshold appears promising but requires confirmation in larger, multicenter studies with extended follow-up to determine its reproducibility and clinical utility.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials