Evidence map›Paper›PMID 41640435›Full record

ArticleFrontiers in oncology2025

Pencil beam scanning proton lattice radiotherapy: single-field versus multi-field optimization.

Shouyi Wei, Lee Xu, Hang Qi, Ajay Zheng, Milo Vermeulen, Annemarie Shepherd, Kaled Alektiar, Nancy Y Lee, Richard Bakst, Chandan Guha and 8 more

Abstract read
In one paragraph

Article in Frontiers in oncology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

18 authors.

Shouyi WeiNew York Proton Center, New York, NY, United States.
Lee XuNew York Proton Center, New York, NY, United States.
Hang QiNew York Proton Center, New York, NY, United States.
Ajay ZhengNew York Proton Center, New York, NY, United States.
Milo VermeulenNew York Proton Center, New York, NY, United States.
Annemarie ShepherdDepartment of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY, United States.
Kaled AlektiarDepartment of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY, United States.
Nancy Y LeeDepartment of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY, United States.
Richard BakstDepartment of Radiation Oncology, Icahn School of Medicine at Mount Sinai, New York, NY, United States.
Chandan GuhaDepartment of Radiation Oncology, Albert Einstein College of Medicine, New York, NY, United States.
Pingfang TsaiNew York Proton Center, New York, NY, United States.
Minglei KangNew York Proton Center, New York, NY, United States.
Xiaodong WuExecutive Medical Physics Associates, Miami, FL, United States.
Irini YacoubNew York Proton Center, New York, NY, United States.
Jehee Isabelle ChoiNew York Proton Center, New York, NY, United States.
Arpit ChhabraNew York Proton Center, New York, NY, United States.
Charles B SimoneNew York Proton Center, New York, NY, United States.
Haibo LinNew York Proton Center, New York, NY, United States.

Funding

X-RAY CRYSTALLOGRAPHYP30CA008748 · NCI · SLOAN-KETTERING INSTITUTE FOR CANCER RES · PI SELWYN M VICKERS · 1985 to 2026
$347.4M
NCI NIH HHS P30 CA008748
6 · The paper itself

Abstract

Objective: To evaluate the advantages and disadvantages of single-field versus multi-field optimization in the clinical implementation of pencil beam scanning (PBS) proton lattice radiotherapy (LRT). Methods: LRT proton plans were created retrospectively for 12 patients with head-and-neck, thoracic, or abdominal bulky tumors, averaging a gross tumor volume (GTV) of 1011.1 cc (between 333 cc and 3546 cc). The plans were developed in the RayStation treatment planning system (version 2023B), adhering to established consensus guidelines for prescription dose and planning goals. For each plan, 6-8 vertices with an average diameter of 1.4 cm were positioned approximately 3.5 cm apart. The prescription was 18 Gy to each vertex and 3 Gy to the GTV. Single-field optimization (SFO) and multi-field optimization (MFO) techniques were employed. The dosimetric parameters of GTV Dmean, D95%, generalized equivalent uniform dose (gEUD a=-10), vertex D90%, peak-to-valley dose ratio (PVDR), and skin D1% were used for plan quality assessment. Plan robustness was also investigated by comparing dose metrics between the nominal and second worst-case scenarios in the robust analysis. Results: For all 12 patients, both SFO and MFO plans achieved a PVDR close to 4 across the three treatment sites. No significant differences in primary dose metrics were observed between SFO and MFO plans, except for skin D1%, which was reduced by an average of 25% in the MFO plans (p<0.05). Robustness evaluation indicated larger deviations in PVDR, GTV Dmean, and skin D1% between nominal and second worst-case scenarios for MFO plans compared to SFO (p<0.05). Conclusion: Both SFO and MFO techniques can be reliably implemented with current proton beam quality standards and advanced treatment planning algorithms. While SFO offers better plan robustness in maintaining the originally optimized metrics under various treatment-related uncertainties, MFO enhances the ability to spare critical organs.

Indexed as

lattice radiation therapy (LRT)MFOpencil beam scanningproton therapySFO

Identifiers

PMID41640435
PMCPMC12865407

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.