ArticleMagnetic resonance in medicine2026
Respiratory Motion-Corrected Model-Based 3D Water-Fat MRA of the Thorax at 0.55 T.
Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Respiratory Motion-Corrected Model-Based 3D Water-Fat MRA of the Thorax at 0.55 T.Magnetic resonance in medicine · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
purposeThe goal of this study was to develop a 5-min 3D MRA acquisition at 0.55 T with predictable scan time, 100% data efficiency, and robust water-fat separation.
methodsFor full data efficiency, the proposed method combined self-gating with retrospective motion correction while ensuring a predictable 5-min scan time. Water-fat separation was implemented using a model-based Dixon reconstruction. Evaluation in 18 volunteers compared results to navigator-gated reference scans with nominal scan times of 5 and 10 min via a Likert scale blinded expert rating. Susceptibility to irregular breathing patterns was also analyzed.
resultsThe expert rating for image quality was 4.22 for the proposed method, 3.89 for the 5-min navigator-gated scan and 4.43 for the 10-min navigator-gated scan. Ranking the three methods revealed moderate inter-rater reliability of 0.46, suggesting only minor differences. While navigator-gated acquisitions deviated from the expected scan time by -2.26 to 2.86 min and -3.91 to 4.54 min for the 5- and 10-min protocols respectively, the proposed method deviated only by -0.17 to 0.45 min. The self-gated method further avoided saturation artifacts from the cross-beam navigator, allowing better distinction of the right pulmonary veins. Image quality for the proposed method was also less susceptible to irregular breathing patterns.
conclusionWhole-thorax MRA acquisitions with water-fat separation and predictable scan times were successfully acquired in 18 volunteers at 0.55 T. The proposed method demonstrated on average better image quality than navigator-gated acquisitions of the same nominal scan time while mitigating limitations of prospective navigator gating.