Evidence map›Paper›PMID 41637610›Full record

ArticleBulletin of the Hospital for Joint Disease (2013)2025

Superior clavicle plating using low-profile, precontoured locking plates has low complication and low hardware removal rate.

Abhishek Ganta, Sanjit R Konda, Kenneth A Egol

Abstract read
In one paragraph

Article in Bulletin of the Hospital for Joint Disease (2013), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Abhishek GantaDivision of Orthopedic Trauma Surgery, Department of Orthopedic Surgery, NYU Langone Health, NYU Langone Orthopedic Hospital, New York, New York.
Sanjit R KondaDivision of Orthopedic Trauma Surgery, Department of Orthopedic Surgery, NYU Langone Health, NYU Langone Orthopedic Hospital, New York, New York.
Kenneth A EgolDivision of Orthopedic Trauma Surgery, Department of Orthopedic Surgery, NYU Langone Health, NYU Langone Orthopedic Hospital, New York, New York.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThe purpose of this study was to describe our experience using superiorly applied low-profile locking plates for the operative fixation of displaced midshaft clavicle fractures (MCFs). STUDY

designThis was a retrospective analysis performed at an academic institution.

resultsEighty-three patients who presented with displaced, shortened MCFs were treated operatively by a single surgeon at our institution over a 10-year period. All patients received a precontoured low-profile locking plate applied in the superior position. A displaced midshaft clavicle fracture was fixed operatively using a precountered low-profile 2.7/3.5 mm locking plate applied in the superior position. Data were analyzed to evaluate time to union, final shoulder range of motion, incidence of hardware removal, and rate of postoperative complications. The cohort was 66.2% male with an average age at initial injury of 36.5 ± 14.1 years. At a mean of 3.6 ± 1.9 months, 99% of patients had united their fracture. At an average of 7.37-month follow-up, mean range of motion was 174° forward elevation, 173° abduction, 82° external rotation, and internal rotation to T7. Using the short musculoskeletal functional assessment (SMFA), the mean functional outcome index score was 4.12, bothersome index was 1.94, activity index was 1.55, emotion index was 2.51, arm and hand index was 1.14, mobility index was 0.68, and total index was 1.56. Ninety-two percent of patients had retained their hardware. There was 1 incidence of each of the following complications: infection, nonunion, hardware failure, and deep vein thrombosis.

conclusionSuperior clavicle plating using precontoured low-profile locking plates is an acceptable treatment modality for displaced MCF. This method yields excellent results regarding time to union, shoulder range of motion, incidence of hardware removal, and the rate of postoperative complications. Patients considering operative fixation of displaced MCF should be counseled accordingly.

Indexed as

Bone PlatesClavicleFracture Fixation, InternalFractures, BoneAdolescentAdultDevice RemovalFemaleFracture HealingHardware RemovalHumansMaleMiddle AgedPostoperative ComplicationsProsthesis DesignRange of Motion, Articularclavicle fractureupper extremity trauma

Identifiers

PMID41637610
PMCPMC12742486

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked