Evidence map›Paper›PMID 41634800›Full record

ArticleBiomedical engineering online2026

The effect of using patient-specific guides for total knee replacement without hardware removal in complex post-traumatic arthritis: an in-vitro study.

Chi-Pin Hsu, Chun-Chieh Chen, Yi-Sheng Chan, Chen-Te Wu, Jeng-Ywan Jeng, Alvin Chao-Yu Chen

Abstract read
In one paragraph

Article in Biomedical engineering online, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Chi-Pin Hsu *Department of Mechanical Engineering, Ming Chi University of Technology, New Taipei City, Taiwan.
Chun-Chieh Chen *Department of Orthopaedic Surgery, Chang Gung Memorial Hospital-Linkou Branch, No. 5, Fuxing Street, Guishan District, Taoyuan, Taiwan.
Yi-Sheng ChanDepartment of Orthopedic Surgery, Keelung Chang Gung Memorial Hospital, Keelung, Taiwan.
Chen-Te WuDepartment of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Taoyuan, Taiwan.
Jeng-Ywan JengTaiwan High Speed 3D Printing Research Center, National Taiwan University of Science and Technology, Taipei, Taiwan.
Alvin Chao-Yu ChenDepartment of Orthopaedic Surgery, Chang Gung Memorial Hospital-Linkou Branch, No. 5, Fuxing Street, Guishan District, Taoyuan, Taiwan. alvinchen@cgmh.org.tw.

Funding

Chang Gung Memorial Hospital, Linkou CMRPG3K1601Chang Gung Memorial Hospital, Linkou CMRPG3K1621
6 · The paper itself

Abstract

backgroundPost-traumatic knee replacement (PTKR) is frequently complicated by the presence of retained metallic hardware around the joint, which limits the use of intramedullary alignment guides. Consequently, extramedullary jigs are often required, although they may increase radiation exposure and reduce alignment precision. Patient-specific guides (PSGs), generated from medical imaging and produced via 3D printing, offer a potential alternative for improving accuracy in complex surgical scenarios. This study aimed to assess the accuracy of PSGs in PTKR using in-vitro knee models with and without retained hardware.

methodsCT images of arthritic knees were used to generate 3D-printed anatomical models. Metallic plates and screws were subsequently mounted to replicate typical post-traumatic hardware configurations. These phantoms underwent CT scanning for virtual surgical planning, and patient-specific guides (PSGs) were designed based on the reconstructed preoperative models. In-vitro distal femoral and proximal tibial resections were then performed by a surgeon using the corresponding PSGs. After the simulated procedures, all phantoms were re-scanned to quantify PSG positioning accuracy and resection angles.

resultsKnee phantoms with hardware exhibited shape deviations 17-18.5 times greater than those without hardware (p < 0.05). PSG positioning errors averaged 0.68 mm and 2.83° in hardware models, compared to 0.55 mm and 1.32° in non-hardware models. Resection angle errors in hardware phantoms ranged from 2.4° to 3.1°, significantly higher than in the non-hardware group.

conclusionsBased on the in-vitro experimental findings, PSGs allow PTKR to be performed without the removal of retained hardware while achieving accuracy that exceeds that of traditional extramedullary alignment techniques. Although hardware presence results in a quantifiable reduction in accuracy, PSGs continue to demonstrate improved alignment precision and contribute to enhanced workflow efficiency in the context of complex PTKR.

Indexed as

ArthritisArthroplasty, Replacement, KneeSurgery, Computer-AssistedHardware RemovalHumansPhantoms, ImagingPrinting, Three-DimensionalTomography, X-Ray Computed3D printingPatient-specific instrumentPost-traumatic arthritisSurgical guideTotal knee replacement

Identifiers

PMID41634800
PMCPMC12997892

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.