Evidence map›Paper›PMID 41634238›Full record

Article3D printing in medicine2026

3D printing enabled biomechanical evaluation of a novel expandable wedge spacer for atlantoaxial reduction.

Chih-Chang Chang, Shao-Fu Huang, Rong-Chen Lin, Chun-Li Lin

Abstract read
In one paragraph

Article in 3D printing in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Chih-Chang ChangDepartment of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan.
Shao-Fu HuangDepartment of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan.
Rong-Chen LinDepartment of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan.
Chun-Li LinDepartment of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan. cllin2@nycu.edu.tw.

Funding

National Science and Technology Council 112-2622-E-A49-030
6 · The paper itself

Abstract

Atlantoaxial subluxation (AAS) is a severe instability of the craniovertebral junction that may cause progressive spinal cord compression and neurological impairment. Achieving complete reduction remains challenging when anterior inclination deformity of the atlas limits posterior traction. This study introduces a novel titanium alloy expandable wedge-shaped spacer designed to correct the anterior inclination of the atlantoaxial joint (AAJ) and facilitate controlled distraction and reduction. The implant integrates a two-stage expansion mechanism that enables sequential anterior elevation and fixation stability. To overcome the scarcity of cadaveric specimens, a patient-specific 3D-printed C1–C2 model was reconstructed from clinical CT data to replicate pathological morphology, simulate ligament behavior, and provide a reproducible biomechanical testing platform. Static and fatigue compression tests, performed according to ASTM F2077 and ISO 23089-2, demonstrated superior load-bearing strength (6725 ± 123 N) and long-term durability over 5 million cycles at 1650 N, with an expansion torque of only 52.56 ± 7.54 N·mm. Reduction experiments using the 3D-printed platform showed that the spacer decreased the required traction force by approximately 70% and redirected the reduction trajectory toward the physiological axis. The integration of medical imaging and high-resolution 3D printing enabled precise replication of patient-specific anatomy and standardized mechanical evaluation that is otherwise unachievable with cadaveric models. This study highlights how 3D printing enables patient-specific modeling, quantitative validation, and iterative optimization of implant design—illustrating its critical role in bridging preclinical testing and clinical translation for complex spinal applications.

Indexed as

3D printingAtlantoaxial jointAtlantoaxial subluxationBiomechanical testingC1–C2 reductionCervical spineExpandable spacer

Identifiers

PMID41634238
PMCPMC12874940

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.