Evidence map›Paper›PMID 41633970›Full record

ArticleLight, science & applications2026

Flexible, stretchable, on-chip optical tweezers for high-throughput bioparticle manipulation.

Ziyi He, Jianyun Xiong, Yang Shi, Ting Pan, Shaobiao Chen, Xin Zhang, Yizhen Chen, Xiangxian Wang, Baojun Li, Hongbao Xin

Abstract read
In one paragraph

Article in Light, science & applications, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Ziyi HeGuangdong Provincial Key Laboratory of Nanophotonic Manipulation, Institute of Nanophotonics, College of Physics & Optoelectronic Engineering, Jinan University, Guangzhou, China.
Jianyun XiongGuangdong Provincial Key Laboratory of Nanophotonic Manipulation, Institute of Nanophotonics, College of Physics & Optoelectronic Engineering, Jinan University, Guangzhou, China.
Yang ShiGuangdong Provincial Key Laboratory of Nanophotonic Manipulation, Institute of Nanophotonics, College of Physics & Optoelectronic Engineering, Jinan University, Guangzhou, China.ORCID http://orcid.org/0000-0002-3336-4826
Ting PanGuangdong Provincial Key Laboratory of Nanophotonic Manipulation, Institute of Nanophotonics, College of Physics & Optoelectronic Engineering, Jinan University, Guangzhou, China.
Shaobiao ChenGuangdong Provincial Key Laboratory of Nanophotonic Manipulation, Institute of Nanophotonics, College of Physics & Optoelectronic Engineering, Jinan University, Guangzhou, China.
Xin ZhangGuangdong Provincial Key Laboratory of Nanophotonic Manipulation, Institute of Nanophotonics, College of Physics & Optoelectronic Engineering, Jinan University, Guangzhou, China.
Yizhen ChenSchool of Science, Lanzhou University of Technology, Lanzhou, China.
Xiangxian WangSchool of Science, Lanzhou University of Technology, Lanzhou, China.
Baojun LiGuangdong Provincial Key Laboratory of Nanophotonic Manipulation, Institute of Nanophotonics, College of Physics & Optoelectronic Engineering, Jinan University, Guangzhou, China. baojunli@jnu.edu.cn.ORCID http://orcid.org/0000-0002-7481-7780
Hongbao XinGuangdong Provincial Key Laboratory of Nanophotonic Manipulation, Institute of Nanophotonics, College of Physics & Optoelectronic Engineering, Jinan University, Guangzhou, China. hongbaoxin@jnu.edu.cn.ORCID http://orcid.org/0000-0001-7132-0835

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

High-throughput trapping and precision manipulation of individual pathogenic bioparticles in complex microenvironments are of great importance for in-vitro diagnostics and drug screening. Although optical tweezers have been widely used for bioparticle trapping and manipulation, the throughput, functionality, and adaptability are still limited for on-chip integrated bioparticle manipulation in complex and dynamic bioenvironments. Here, we report flexible, stretchable, on-chip optical tweezers (FSOT) based on large-scale orderly assembled microlenses for high-throughput manipulation of bioparticles in complex bio-environments and on flexible substrates, including soft bio-substrates such as skin and intestines. Large-scale (up to 1000) photonic nanojet effect of the microlenses enables high-throughput trapping, sorting, and modulation of individual bioparticles with sizes ranging from sub-100 nm to tens of micrometers, such as exosomes, bacteria and mammalian cells. Our FSOT exhibits high flexibility, which enables bioparticle trapping and sorting in complex and curved biological microenvironments. Importantly, our FSOT also exhibits high deformability and stretchability, which facilitates the control of inter-cellular distance between trapped neighboring cells, enabling real-time modulating and monitoring the interaction between single pathogenic bacteria and macrophage. Our FSOT represents a new class of on-chip optical tweezers for high-throughput bioparticle trapping and manipulation with the features of high flexibility and stretchability, and holds great promises as an integrated on-chip platform for high-throughput dynamic analysis of bioparticles, for revealing inter-cellular interactions between pathogenic bioparticles and host cells, and for precise drug screening.

Identifiers

PMID41633970
PMCPMC12868836

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.