Evidence map›Paper›PMID 41632399›Full record

ArticleJournal of clinical monitoring and computing2026

Paired assessment of two electromyographic neuromuscular monitors: stimpod NMX450X versus Datex-Ohmeda E-NMT.

Manish Zambre, Ulrich Janssens, Wilfried Cools, Jarne De Mey, Domien Vanhonacker, Hugo Carvalho

Abstract readComparative Study
In one paragraph

Article in Journal of clinical monitoring and computing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Manish ZambreDepartment of Anaesthesia and Perioperative Medicine, Universitair Ziekenhuis Brussel, Brussels, Belgium. Manish.Zambre@vub.be.
Ulrich JanssensDepartment of Anaesthesia and Perioperative Medicine, AZORG Ziekenhuis, Aalst, Belgium.
Wilfried CoolsVrije Universiteit Brussel, Brussels, Belgium.
Jarne De MeyDepartment of Anaesthesia and Perioperative Medicine, Universitair Ziekenhuis Brussel, Brussels, Belgium.
Domien VanhonackerDepartment of Anaesthesia and Perioperative Medicine, Universitair Ziekenhuis Brussel, Brussels, Belgium.
Hugo CarvalhoDepartment of Anaesthesia and Perioperative Medicine, Universitair Ziekenhuis Brussel, Brussels, Belgium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Quantitative neuromuscular monitoring (NMM) is widely recommended, yet its clinical adoption remains limited, partly due to usability issues. This study aimed to compare the clinical performance of two electromyography (EMG)-based NMM devices—the Datex-Ohmeda E-NMT module and the Stimpod NMS450X—under real-world operating room conditions. Twenty-four adult patients undergoing elective non-cardiac surgery were monitored simultaneously with both devices, applied contralaterally. Train-of-four (TOF) counts and TOF ratios were recorded at one-minute intervals. Agreement between devices was assessed using Bland–Altman analysis, repeatability coefficients, and the concordance correlation coefficient (CCC). The Datex-Ohmeda recorded an average of 121 TOF-count and 71 TOF-ratio values per patient, compared with 56 and 39, respectively, for the Stimpod. Inter-device correspondence was low, with numerous missing or physiologically implausible values on the Stimpod stream. The repeatability coefficient was 0.81 (95% CI: 0.80–0.83), indicating poor precision. The CCC was 0.662, consistent with weak agreement. In routine clinical use, the Stimpod NMS450X and Datex-Ohmeda E-NMT demonstrated poor concordance and high variability, likelyinfluenced by device-specific artifacts, connectivity limitations and electrode sensitivity.These findings highlight the need for device-specific validation of EMG NMM, both for clinical practice and for research purposes.

Indexed as

ElectromyographyMonitoring, IntraoperativeNeuromuscular MonitoringAdultAgedFemaleHumansMaleMiddle AgedReproducibility of ResultsDatex-OhmedaElectromyographyNeuromuscular monitoringQuantitative monitoringStimpod

Identifiers

PMID41632399
PMCPMC13194313

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.