Paired assessment of two electromyographic neuromuscular monitors: stimpod NMX450X versus Datex-Ohmeda E-NMT.
Article in Journal of clinical monitoring and computing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Quantitative neuromuscular monitoring (NMM) is widely recommended, yet its clinical adoption remains limited, partly due to usability issues. This study aimed to compare the clinical performance of two electromyography (EMG)-based NMM devices—the Datex-Ohmeda E-NMT module and the Stimpod NMS450X—under real-world operating room conditions. Twenty-four adult patients undergoing elective non-cardiac surgery were monitored simultaneously with both devices, applied contralaterally. Train-of-four (TOF) counts and TOF ratios were recorded at one-minute intervals. Agreement between devices was assessed using Bland–Altman analysis, repeatability coefficients, and the concordance correlation coefficient (CCC). The Datex-Ohmeda recorded an average of 121 TOF-count and 71 TOF-ratio values per patient, compared with 56 and 39, respectively, for the Stimpod. Inter-device correspondence was low, with numerous missing or physiologically implausible values on the Stimpod stream. The repeatability coefficient was 0.81 (95% CI: 0.80–0.83), indicating poor precision. The CCC was 0.662, consistent with weak agreement. In routine clinical use, the Stimpod NMS450X and Datex-Ohmeda E-NMT demonstrated poor concordance and high variability, likelyinfluenced by device-specific artifacts, connectivity limitations and electrode sensitivity.These findings highlight the need for device-specific validation of EMG NMM, both for clinical practice and for research purposes.