ArticleScientific reports2026
Weighted average algorithm adjusted a novel (1 + FOPI)-FOPI-TID controller structure for AGC with integration of non-linearities and cyber-attack.
Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The integration of diverse energy sources and the advent of smart grids have intensified the challenges in load frequency management (LFM). Modern power systems are increasingly vulnerable to inherent nonlinearities, such as generation rate constraints, governor dead bands, boiler dynamics, and communication delays, as well as sophisticated cyber-attacks, which collectively threaten frequency stability and tie-line power balance. To address these challenges, this study proposes a novel cascade controller, designated as (1 + FOPI)-FOPI-TID, for robust automatic generation control in hybrid two-area power systems. The controller uniquely combines fractional-order (FO) dynamics with a tilt-integral-derivative stage and is optimized using a green metaheuristic, the weighted average algorithm (WAA). The WAA effectively balances exploration and exploitation to achieve superior parameter tuning. The proposed control architecture processes both area control error (ACE) and frequency deviation (ΔF) signals through dedicated stages, enabling enhanced disturbance rejection and transient response. The system model incorporates a comprehensive set of nonlinearities and evaluates resilience against resonance-based cyber-attacks. Comprehensive simulation studies under both AC and HVDC tie-line configurations demonstrate that the WAA-optimized (1 + FOPI)-FOPI-TID controller significantly outperforms existing schemes, including PD-PI, PIFOD-(1 + PI), and PIDF(1 + FOD). Key performance metrics show a 45.3% reduction in the integral of time-weighted absolute error (ITAE) and improvements in settling times of 47.7% for ΔF₁ and 32.8% for ΔF₂. Sensitivity analysis confirms robustness under ± 25% parameter variations and random load perturbations. During cyber-attacks, the controller maintains the lowest Rate of Change of Frequency (RoCoF), underscoring its dual capability in stabilizing grid dynamics and mitigating cyber-physical threats. These results validate the controller's potential to enhance operational resilience and reliability in future smart grids.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.