Evidence map›Paper›PMID 41629428›Full record

ArticleScientific reports2026

Weighted average algorithm adjusted a novel (1 + FOPI)-FOPI-TID controller structure for AGC with integration of non-linearities and cyber-attack.

Moses Awal, Michael Robson Atim, Jimmy Nabende Wanzala, Johnes Obungoloch, Mohamed Barakat

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Moses AwalPhysics Department, Mbarara University of Science and Technology, Mbarara, Uganda. mosesawalpower@gmail.com.
Michael Robson AtimPhysics Department, Busitema University, Tororo, Uganda.
Jimmy Nabende WanzalaPhysics Department, Mbarara University of Science and Technology, Mbarara, Uganda. wanzalajimmy@gmail.com.
Johnes ObungolochBiomedical Sciences and Engineering Department, Mbarara University of Science and Technology, Mbarara, Uganda.
Mohamed BarakatECE Department, Giza Engineering Institute, Giza, Egypt.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The integration of diverse energy sources and the advent of smart grids have intensified the challenges in load frequency management (LFM). Modern power systems are increasingly vulnerable to inherent nonlinearities, such as generation rate constraints, governor dead bands, boiler dynamics, and communication delays, as well as sophisticated cyber-attacks, which collectively threaten frequency stability and tie-line power balance. To address these challenges, this study proposes a novel cascade controller, designated as (1 + FOPI)-FOPI-TID, for robust automatic generation control in hybrid two-area power systems. The controller uniquely combines fractional-order (FO) dynamics with a tilt-integral-derivative stage and is optimized using a green metaheuristic, the weighted average algorithm (WAA). The WAA effectively balances exploration and exploitation to achieve superior parameter tuning. The proposed control architecture processes both area control error (ACE) and frequency deviation (ΔF) signals through dedicated stages, enabling enhanced disturbance rejection and transient response. The system model incorporates a comprehensive set of nonlinearities and evaluates resilience against resonance-based cyber-attacks. Comprehensive simulation studies under both AC and HVDC tie-line configurations demonstrate that the WAA-optimized (1 + FOPI)-FOPI-TID controller significantly outperforms existing schemes, including PD-PI, PIFOD-(1 + PI), and PIDF(1 + FOD). Key performance metrics show a 45.3% reduction in the integral of time-weighted absolute error (ITAE) and improvements in settling times of 47.7% for ΔF₁ and 32.8% for ΔF₂. Sensitivity analysis confirms robustness under ± 25% parameter variations and random load perturbations. During cyber-attacks, the controller maintains the lowest Rate of Change of Frequency (RoCoF), underscoring its dual capability in stabilizing grid dynamics and mitigating cyber-physical threats. These results validate the controller's potential to enhance operational resilience and reliability in future smart grids.

Indexed as

(1 + FOPI)-FOPI-TID controllerAutomatic generation controlCyber-attackPower systems nonlinearitiesRandom step loadWeighted average algorithm

Identifiers

PMID41629428
PMCPMC12917270

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.