ArticleBMJ open2026
Device-assessed sleep health among older patients with heart failure: a cross-sectional study using actigraphy.
Article in BMJ open, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivePoor sleep is common among patients with heart failure (HF) and is associated with adverse cardiovascular outcomes. The utility of actigraphy in sleep assessment, especially among older adults, remains underexplored. This study aimed to assess sleep health among older adults with HF using actigraphy and explore associations between sleep parameters and cardiac biomarkers, functional performance and quality of life (QoL).
designA cross-sectional study.
settingThe study was conducted at an outpatient HF clinic within a tertiary cardiology service in a National Health Service hospital in the UK between March and October 2023.
participantsA total of 150 older adults aged ≥65 years with a diagnosis of HF were enrolled.
methodsParticipants were given a wrist-accelerometer to wear for 7 days. On Day 0, patients completed a 4-metre walk test (4MWT), handgrip strength test (HGST), Timed Up and Go test (TUGT), Barthel Index (BI), Kansas City Cardiomyopathy Questionnaire (KCCQ-12) and frailty assessment (Clinical Frailty Scale, CFS). Subsequently, they were fitted with an accelerometer, with the device configured to start recording the following day (Day 1). Sleep outcomes were calculated after a 7-day wear period and averaged across valid nights (minimum 3 nights of recording, noon-to-noon with ≥16 hours wear-time). Sleep parameters studied include average sleep efficiency, sleep period time window, sleep duration, sleep onset and wake up time, wake after sleep onset (WASO), sleep interruptions and Sleep Regularity Index (SRI). Inefficient sleep was defined as sleep efficiency <80%. Regression analysis was used to examine associations between sleep parameters and the previously stated tests and assessments, adjusting for age, gender and comorbidities. OUTCOME MEASURES: The primary outcome measure was sleep efficiency; all other sleep parameters were classified as secondary or exploratory outcomes.
resultsAccelerometry data from 145 participants were analysed; 42% had inefficient sleep based on average sleep efficiency across valid nights. These patients had significantly higher plasma N-terminal pro-B-type natriuretic peptide (NT-proBNP) levels (p=0.044). No statistically significant difference was noted in 4MWT, HGST, TUGT, BI, KCCQ-12 and CFS between patients with sleep efficiency <80% and those with sleep efficiency ≥80%. Lower sleep efficiency was associated with lower BI scores (adjusted β=0.271, p=0.016) and worse frailty (adjusted β=-0.017, p=0.014). Lower SRI was associated with worse New York Heart Association class (adjusted β=-0.009, p=0.007), BI scores (adjusted β=0.310, p<0.001), frailty (adjusted β=-0.017, p<0.001) and QoL (adjusted β=0.344, p=0.001); longer WASO was associated with slower gait speed (adjusted β=-0.039, p=0.040).
conclusionsOlder adults with HF who had inefficient sleep had significantly higher NT-proBNP levels. Lower sleep efficiency was associated with higher functional dependence and frailty. Sleep irregularity was linked to HF symptom load, frailty, functional performance and QoL, while sleep fragmentation was associated with impaired gait speed.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.