Evidence map›Paper›PMID 41627527›Full record

ArticleArchives of orthopaedic and trauma surgery2026

Leg length and offset in short-stem total hip arthroplasty: is a single offset-implant sufficient to restore the hip rotation centre within a range of 5 mm?

Felix Olk, Bernd Bittersohl, Jürgen Babisch, Hagen Mittelstädt, Marcus Jäger, Rüdiger Krauspe, Christoph Zilkens

Abstract read
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Felix OlkDepartment of Orthopaedic Surgery Ex-Director: Univ.-Prof. Dr. med. R. Krauspe, Heinrich Heine University Düsseldorf, Düsseldorf, Germany. felix.olk@hhu.de.
Bernd BittersohlDepartment of Orthopaedic Surgery Ex-Director: Univ.-Prof. Dr. med. R. Krauspe, Heinrich Heine University Düsseldorf, Düsseldorf, Germany.
Jürgen BabischDepartment of trauma, hand and orthopaedic surgery, Helios Klinikum Erfurt, Erfurt, Germany.
Hagen MittelstädtDepartment of trauma and orthopaedic surgery, University Hospital Schleswig-Holstein, Lübeck, Germany.
Marcus JägerDepartment of Orthopaedic Surgery Director: Univ.-Prof. Dr. med. M. Jäger St.Marien-Hospital Muelheim an der Ruhr GmbH, University of Duisburg-Essen, Essen, Germany.
Rüdiger KrauspeDepartment of Orthopaedic Surgery Ex-Director: Univ.-Prof. Dr. med. R. Krauspe, Heinrich Heine University Düsseldorf, Düsseldorf, Germany.
Christoph ZilkensDepartment of Orthopaedic Surgery Ex-Director: Univ.-Prof. Dr. med. R. Krauspe, Heinrich Heine University Düsseldorf, Düsseldorf, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionShort-stem total hip arthroplasty (THA) has gained popularity due to its bone-preserving properties and improved physiological load transmission to the proximal femur. Despite these advantages, the ability of short-stem implants to reliably restore leg length and offset remains debated. This study evaluates whether a single offset implant is sufficient for accurate anatomical reconstruction or if multiple offset options are necessary. MATERIAL AND

methodsA total of 148 anteroposterior pelvic radiographs of patients scheduled for short-stem THA were analysed using MediCAD® software. Femoral offset and leg length were measured, and the accuracy of anatomical reconstruction was assessed within a 5-mm target range. Comparisons were made between a single offset (130°) implant and a dual-offset system (130° and 119°) using the McNemar-Bowker test.

resultsWith a single 130° CCD (Caput-collum-diaphyseal) offset implant, 55.7% (82/148) of cases achieved satisfactory leg length and offset restoration. The use of a dual-offset system improved accuracy to 79.1% (117/148), demonstrating a statistically significant advantage (p < 0.001). DISCUSSION: The study highlights the need for at least two CCD-angle-offset combinations in short-stem THA to address anatomical variability. A dual-offset system enhances accuracy, reduces biomechanical imbalances, and therefore we expect improvements in clinical outcomes, particularly in teaching hospitals where standardization is essential.

Indexed as

Arthroplasty, Replacement, HipHip JointHip ProsthesisAgedFemaleFemurHumansLeg Length InequalityMaleMiddle AgedProsthesis DesignRotationCalcar-GuidedCaput-Collum-Diaphyseal AngleCCD AngleExtended OffsetFemoral OffsetLeg LengthShort stemTemplatingTotal Hip ArthroplastyVarus

Identifiers

PMID41627527
PMCPMC12864294

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.