Evidence map›Paper›PMID 41627520›Full record

ReviewArchives of orthopaedic and trauma surgery2026

Intraoperative evaluation of rotational alignment in minimally invasive plate osteosynthesis for humeral shaft fractures using combined fluoroscopic and endoscopic assistance: surgical technique, clinical outcomes, and literature review.

Chang-Heng Liu, Ping-Jui Tsai, I-Jung Chen, Po-Ju Lai, Chih-Yang Lai

Abstract readReview
In one paragraph

Review in Archives of orthopaedic and trauma surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Chang-Heng LiuDepartment of Orthopaedic surgery, Linkou Chang Gung Memorial Hospital, Taoyuan City, Taiwan.
Ping-Jui TsaiDepartment of Orthopaedic surgery, Linkou Chang Gung Memorial Hospital, Taoyuan City, Taiwan.
I-Jung ChenDepartment of Orthopaedic surgery, Linkou Chang Gung Memorial Hospital, Taoyuan City, Taiwan.
Po-Ju LaiDepartment of Orthopaedic surgery, Linkou Chang Gung Memorial Hospital, Taoyuan City, Taiwan.
Chih-Yang LaiDepartment of Orthopaedic surgery, Linkou Chang Gung Memorial Hospital, Taoyuan City, Taiwan. james770516@hotmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionMinimally invasive plate osteosynthesis (MIPO) has become an established method for treating humeral shaft fractures; however, achieving accurate intraoperative rotational alignment remains challenging. This study describes an intraoperative evaluation technique using combined fluoroscopic and endoscopic assistance to improve the precision and objectivity of rotational correction during MIPO. MATERIALS AND

methodsFrom September 2019 to June 2023, twenty adult patients with simple transverse or wedge-type midshaft humeral fractures (AO/OTA type A or B) who underwent MIPO fixation were retrospectively reviewed. Demographic data, operative time, intraoperative fluoroscopy time, and postoperative outcomes were analyzed. Rotational difference (RD) between the operated and contralateral arms was measured using computed tomography (CT). Continuous variables between AO type A and B fractures were compared using the Mann–Whitney U test (p < 0.05).

resultsThe mean operative time was 113.5 min, and the mean fluoroscopy time was 75.9 s, which was significantly longer in AO type B fractures (p < 0.05). The average RD was 7.4° ± 4.7° (range, 1.9˚–17.5°). All fractures achieved union, with 18 cases healing within 3–6 months and 2 cases within 9–12 months. Mean angulation was 2.1° (coronal) and 2.0° (sagittal), and mean translation was 1.1 mm (coronal) and 1.3 mm (sagittal). No iatrogenic neurovascular injuries or infections were observed. There were no significant differences between AO type A and type B fractures in union rate or alignment parameters.

conclusionsCombined fluoroscopic–endoscopic assistance enables objective intraoperative evaluation of humeral rotational alignment during MIPO without compromising soft-tissue preservation. This technique provides reliable reduction quality and consistent healing outcomes in AO type A and B humeral shaft fractures, representing a practical refinement of standard MIPO principles.

Indexed as

Bone PlatesEndoscopyFracture Fixation, InternalHumeral FracturesMinimally Invasive Surgical ProceduresAdultAgedFemaleFluoroscopyHumansMaleMiddle AgedOperative TimeRetrospective StudiesRotationTreatment Outcome

Identifiers

PMID41627520
PMCPMC12864267

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.