ArticleJournal of pharmaceutical analysis2026
Development of a dual-chamber derivatization method for the determination of cyanide in sodium nitroprusside and its preparation via HS-GC-ECD.
Article in Journal of pharmaceutical analysis, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The acute toxicity of cyanide and its pharmaceutical residues has fueled interest in the development of analytical methods for its determination, particularly for sodium nitroprusside (SNP), a widely used vasodilator with potential cyanide residues. In this study, a dual-chamber derivatization bottle was designed to establish an interconnected gas environment, thereby facilitating chloramine T-mediated cyanide conversion to cyanogen chloride (CNCl) without direct contact with SNP. Subsequent determination of the analytes was undertaken using a headspace-gas chromatography-electron capture detector (HS-GC-ECD). The challenges of analyzing cyanide and the rapid degradation of SNP were addressed simultaneously. The method was subjected to rigorous validation, encompassing specificity, linearity, limit of detection (LOD), limit of quantitation (LOQ), accuracy, precision, and robustness. The validation process revealed a notable degree of linearity within the range of 0.012-1.56 μg/mL, with a LOQ of 12.0 ng/mL. The method was found to be both accurate and precise, thus satisfying the requisite criteria. This method facilitates reliable cyanide monitoring in degradation-prone pharmaceuticals.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.