Evidence map›Paper›PMID 41626227›Full record

ArticleFrontiers in medicine2026

Application of a portable sealed positive pressure infusion device in a porcine model of hemorrhagic shock.

Jinsong Tao, Yuandan Lai, Caiyuan Fu, Yiru Lin, Yuemin Zhang, Wenting Huang, Zhicheng Huang, Chunlan Tian, Weihang Wu, Meijiao Lin

Abstract read
In one paragraph

Article in Frontiers in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Jinsong Tao *Department of General Surgery, Fuzong Teaching Hospital of Fujian University of Traditional Chinese Medicine (900th Hospital), Fuzhou, Fujian, China.
Yuandan Lai *Department of General Surgery, 900th Hospital of PLA Joint Logistic Support Force, Fuzhou, Fujian, China.
Caiyuan FuDepartment of General Surgery, 900th Hospital of PLA Joint Logistic Support Force, Fuzhou, Fujian, China.
Yiru LinDepartment of General Surgery, Fuzong Teaching Hospital of Fujian University of Traditional Chinese Medicine (900th Hospital), Fuzhou, Fujian, China.
Yuemin ZhangDepartment of General Surgery, Fuzong Teaching Hospital of Fujian University of Traditional Chinese Medicine (900th Hospital), Fuzhou, Fujian, China.
Wenting HuangDepartment of General Surgery, 900th Hospital of PLA Joint Logistic Support Force, Fuzhou, Fujian, China.
Zhicheng HuangDepartment of General Surgery, Fuzong Teaching Hospital of Fujian University of Traditional Chinese Medicine (900th Hospital), Fuzhou, Fujian, China.
Chunlan TianNursing College, Fujian University of Traditional Chinese Medicine, Fuzhou, Fujian, China.
Weihang Wu *Department of General Surgery, 900th Hospital of PLA Joint Logistic Support Force, Fuzhou, Fujian, China.
Meijiao Lin *Department of General Surgery, Fuzong Teaching Hospital of Fujian University of Traditional Chinese Medicine (900th Hospital), Fuzhou, Fujian, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Hemorrhagic shock is a leading cause of trauma-related mortality in military and disaster settings, necessitating prompt fluid resuscitation. Conventional infusion methods, which rely on elevating fluid containers to generate hydrostatic pressure, risk secondary injury and are less efficient during prehospital transport. We developed a wearable, portable, sealed positive-pressure infusion device to optimize fluid administration in austere environments. Methods: Ten male Bama miniature pigs underwent controlled hemorrhagic shock (mean arterial pressure [MAP] < 60 mmHg, induced by blood withdrawal until approximately 40-45% of estimated total blood volume [70 mL/kg body weight] and maintained for 30 min). Animals were randomized to receive resuscitation with 6% hydroxyethyl starch 130/0.4 in saline at 10 mL/min using either the novel device or conventional manual pressure infusion. Vital signs and blood parameters (e.g., activated partial thromboplastin time [APTT]) were measured at baseline, shock phase, 1 h post-resuscitation, and upon completion of resuscitation. Resuscitation time, fluid volume, and maximum infusion line pressure were recorded. Results: All animals achieved successful resuscitation (100% immediate survival). During a 7-day follow-up, one animal in each group died (20%, Conclusion: The portable sealed positive-pressure infusion device provided stable pressure, improved infusion performance, and maintained safety. It represents a feasible solution for managing hemorrhagic shock in prehospital austere settings.

Indexed as

fluid resuscitationhemorrhagic shockporcine modelportable infusion deviceprehospital care

Identifiers

PMID41626227
PMCPMC12852321

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.