Evidence map›Paper›PMID 41624321›Full record

ArticleJournal of hand surgery global online2025

Enhanced Diagnostic Accuracy of Fast-Field Echo Resembling a Computed Tomography Using Restricted Echo-Spacing for Hand Tendon Injuries: A Comparative Study.

Yukari Matsuzawa, Yusuke Matsuura, Kaoru Kitsukawa, Takahiro Yamazaki, Kayo Inaguma, Seiji Ohtori

Abstract read
In one paragraph

Article in Journal of hand surgery global online, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yukari MatsuzawaDepartment of Orthopaedic Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan.
Yusuke MatsuuraDepartment of Orthopaedic Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan.
Kaoru KitsukawaComprehensive Radiology Center, Chiba University Hospital, Chiba, Japan.
Takahiro YamazakiDepartment of Orthopaedic Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan.
Kayo InagumaDepartment of Orthopaedic Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan.
Seiji OhtoriDepartment of Orthopaedic Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Fast-field echo resembling a computed tomography using restricted echo-spacing (FRACTURE), a magnetic resonance imaging (MRI) sequence (Philips Healthcare) providing computed tomography-like bone contrast, enables excellent visualization of bones and tendons. Volume rendering (VR) images created from this sequence show anatomical details of a patient's actual structures. This study evaluated the diagnostic performance of FRACTURE and its VR images for visualizing wrist tendons on MRI images from patients and healthy individuals. Methods: Twenty subjects were included, 10 patients with tendon injuries and 10 healthy individuals who underwent MRI scanning. The imaging protocols were FRACTURE (with VR images), T2-weighted imaging (T2WI), and proton density-weighted volumetric isotropic turbo-spin-echo acquisition (PD-VISTA). An orthopedic surgeon, a hand-surgery specialist, and a radiologist not involved in the surgeries used three methods to interpret the images: FRACTURE multiplanar reconstruction, FRACTURE VR, and PD-VISTA + T2WI. The assessment criteria included tendon injury diagnostic accuracy, interpretation time, and ease-of-interpretation scoring. Diagnostic accuracy was calculated as the correct diagnosis rate. Interpretation time and scoring were analyzed by paired Results: Fast-field echo resembling a computed tomography using restricted echo-spacing VR showed the highest tendon injury diagnostic accuracy, with considerably better interpretation time performance and ease-of-interpretation scoring versus PD-VISTA + T2WI. In the surgical cases, the tendon rupture sites on FRACTURE images corresponded to the intraoperative findings. Conclusions: Fast-field echo resembling a computed tomography using restricted echo-spacing was excellent across all assessment criteria, and FRACTURE VR had particularly high diagnostic performance and clinical utility. Although obliquely oriented tendons, such as of the thumb and little finger, require consideration of the magic angle effect, clear visualization of these tendons was possible with appropriate positioning. Additionally, FRACTURE's high tendon visualization capability enabled the identification of anatomical variations, enhancing its usefulness in clinical hand-surgery practice. Clinical relevance: Tendon injury diagnosis was faster and more accurate with FRACTURE VR than with conventional sequences.

Indexed as

Diagnostic accuracyHand tendonMRITendon injuriesVolume rendering image

Identifiers

PMID41624321
PMCPMC12859618

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.