ArticlePhotoacoustics2026

Blood-mimicking dye phantoms for evaluating photoacoustic oximetry accuracy.

Yong Zhou, Zixin Wang, Keith A Wear, T Joshua Pfefer, Jesse V Jokerst, William C Vogt

Abstract read
In one paragraph

Article in Photoacoustics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yong ZhouCenter for Devices and Radiological Health, US Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA.
Zixin WangDepartment of NanoEngineering, University of California, La Jolla, San Diego, CA 92093, United States.
Keith A WearCenter for Devices and Radiological Health, US Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA.
T Joshua PfeferCenter for Devices and Radiological Health, US Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA.
Jesse V JokerstDepartment of NanoEngineering, University of California, La Jolla, San Diego, CA 92093, United States.
William C VogtCenter for Devices and Radiological Health, US Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Many proposed clinical applications of photoacoustic imaging (PAI) rely on relative or absolute measurements of blood oxygen saturation (sO2), and evaluation of oximetry measurement accuracy is crucial for assessing device performance. Available bench test methods use phantoms connected to blood flow circuits with tunable oxygenation, but these methods are complex, costly, and pose biohazard safety risks. To address these issues, we have developed stable and tunable blood-mimicking solutions using binary mixtures of commercially available near-infrared organic dyes (NIR746A and IRA980) to enable non-biological phantom-based PAI oximetry test methods. We used spectrophotometry and a custom PA spectroscopy system to characterize dye extinction and PA response at 750 nm and 850 nm, then formulated various dye recipes mimicking sO2 levels from 40 % to 100 %. We then used a custom PAI system to image breast-mimicking polyacrylamide hydrogel phantoms with embedded tubes injected with static volumes of either dye solutions or bovine blood deoxygenated using sodium dithionite. Phantom testing with dyes produced similar performance metrics to blood, with root-mean-squared difference (RMSD) values between photoacoustic sO2 and reference sO2 of 6-17 % for blood and 4-18 % for dyes, sensitivity (slope of the regression line) ranged from 0.4 to 0.7 for blood and 0.4-0.9 for dyes, and depth-averaged bias ranged from 4 % to 17 % for blood and 3-10 % for dyes. These blood-mimicking dyes may offer a simpler, cheaper, safer, and more stable approach to evaluate PAI oximetry accuracy compared to traditional blood flow phantoms. This tool could facilitate establishment of less burdensome and more reproducible phantom-based PAI test methods, ultimately expediting clinical adoption of PAI technology.

Indexed as

CO-oximetryMultispectralOxygenationPhantomsPhotoacoustic imaging

Identifiers

PMID41624274
PMCPMC12854982

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.