ArticlePhotoacoustics2026
Blood-mimicking dye phantoms for evaluating photoacoustic oximetry accuracy.
Article in Photoacoustics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Improved quantification of photoacoustic biomarkers through residual-based noise masking.Photoacoustics · 2026Article
- Impact of skin pigmentation on photoacoustic tomography: a phantom study.Biophotonics discovery · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Many proposed clinical applications of photoacoustic imaging (PAI) rely on relative or absolute measurements of blood oxygen saturation (sO2), and evaluation of oximetry measurement accuracy is crucial for assessing device performance. Available bench test methods use phantoms connected to blood flow circuits with tunable oxygenation, but these methods are complex, costly, and pose biohazard safety risks. To address these issues, we have developed stable and tunable blood-mimicking solutions using binary mixtures of commercially available near-infrared organic dyes (NIR746A and IRA980) to enable non-biological phantom-based PAI oximetry test methods. We used spectrophotometry and a custom PA spectroscopy system to characterize dye extinction and PA response at 750 nm and 850 nm, then formulated various dye recipes mimicking sO2 levels from 40 % to 100 %. We then used a custom PAI system to image breast-mimicking polyacrylamide hydrogel phantoms with embedded tubes injected with static volumes of either dye solutions or bovine blood deoxygenated using sodium dithionite. Phantom testing with dyes produced similar performance metrics to blood, with root-mean-squared difference (RMSD) values between photoacoustic sO2 and reference sO2 of 6-17 % for blood and 4-18 % for dyes, sensitivity (slope of the regression line) ranged from 0.4 to 0.7 for blood and 0.4-0.9 for dyes, and depth-averaged bias ranged from 4 % to 17 % for blood and 3-10 % for dyes. These blood-mimicking dyes may offer a simpler, cheaper, safer, and more stable approach to evaluate PAI oximetry accuracy compared to traditional blood flow phantoms. This tool could facilitate establishment of less burdensome and more reproducible phantom-based PAI test methods, ultimately expediting clinical adoption of PAI technology.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.