Evidence map›Paper›PMID 41620523›Full record

ArticleScientific reports2026

Computational design of foldable origami-based compressive ultrasound sensing.

Nicolas Hochuli, Tim Wünsch, Weiye Li, Xiaohan Han, Daniel Razansky, Tino Stanković, Héctor Estrada

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Nicolas Hochuli *Engineering Design and Computing Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland.
Tim Wünsch *Institute of Pharmacology and Toxicology and Institute for Biomedical Engineering, Faculty of Medicine, University of Zurich, Zurich, Switzerland.
Weiye LiInstitute of Pharmacology and Toxicology and Institute for Biomedical Engineering, Faculty of Medicine, University of Zurich, Zurich, Switzerland.
Xiaohan HanInstitute of Pharmacology and Toxicology and Institute for Biomedical Engineering, Faculty of Medicine, University of Zurich, Zurich, Switzerland.
Daniel RazanskyInstitute of Pharmacology and Toxicology and Institute for Biomedical Engineering, Faculty of Medicine, University of Zurich, Zurich, Switzerland.
Tino StankovićEngineering Design and Computing Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland. tinos@ethz.ch.
Héctor EstradaInstitute of Pharmacology and Toxicology and Institute for Biomedical Engineering, Faculty of Medicine, University of Zurich, Zurich, Switzerland. hector.estrada@pharma.uzh.ch.

Funding

Eidgenössische Technische Hochschule Zürich Research Grant 23-1 ETH-35Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung CRSK-3_220930
6 · The paper itself

Abstract

Ultrasound imaging is an essential part of the modern clinical routine. However, its dependence on costly multichannel electronics limits its use in chronic monitoring of disease. Single-detector compressed-sensing approaches have been proposed to simplify the signal acquisition pipeline, but they suffer from reduced acoustic sensitivity due to reliance on multiple scattering topologies. We propose foldable origami structures with built-in ultrasound sensing capabilities for single-pixel imaging that increase the acoustic sensitivity by leveraging a foldable transducer geometry. By detecting ultrasound fields at various origami folding states, target images in two- and three-dimensions are recovered using model-based reconstruction techniques. We simulated the Foldable Origami-based Compressive Ultrasound Sensing (FOCUS) concept and inverse designed the origami geometry for maximum imaging performance. We quantified the performance of the FOCUS concept with the reconstruction accuracy of synthetic target images including point-scatterers and vessel-like structures, reaching an average structure similarity index measure of 0.63 and [Formula: see text] error of 11.89. We showed that the optimized FOCUS pattern remains effective even when exposed to geometric distortions and electrical noise. Our approach can tailor the FOCUS design to various targets, scales, and applications, potentially transforming ultrasound imaging devices through miniaturized single-channel electronics.

Identifiers

PMID41620523
PMCPMC12916773

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.