Design and Validation of an Arduino-Based, Cost-Effective Heated Anesthesia Induction Chamber for Mice.

Anthony Corea, Kyle Tucker, Colin E Benites, Christopher Arellano, Diego Celdran-Bonafonte

Abstract read
In one paragraph

Article in Journal of the American Association for Laboratory Animal Science : JAALAS, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Anthony CoreaCollege of Veterinary Medicine, University of Arizona, Tucson, Arizona.
Kyle TuckerCollege of Engineering, University of Arizona, Tucson, Arizona.
Colin E BenitesCollege of Medicine, Department of Orthopedic Surgery, University of Arizona, Tucson, Arizona.
Christopher ArellanoCollege of Medicine, Department of Orthopedic Surgery, University of Arizona, Tucson, Arizona.
Diego Celdran-BonafonteCollege of Veterinary Medicine, University of Arizona, Tucson, Arizona.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Rodents are highly susceptible to peri-anesthetic hypothermia because of their small body size, large surface area to volume/mass ratio, and anesthetic-induced thermoregulatory depression. Early heat loss during induction is rapid and can be difficult to reverse, emphasizing the need for simple, reliable warming solutions during anesthetic induction. We designed and validated a low-cost, Arduino-controlled heated induction chamber for mice and evaluated its safety and efficacy in preventing early hypothermia. The device uses proportional integral derivative control to regulate a heated chamber floor. Bench testing quantified warm-up time, steady-state stability, and the temperature offset between the embedded thermistor and surface temperature. In a randomized, paired, repeated-measures design, 10 adult C57BL/6 mice underwent 2 experimental conditions, unheated induction compared with heated induction, followed by a standardized 10-minute anesthetic maintenance phase on a prewarmed, heated surgical monitoring platform. Core body temperature was measured with intraperitoneal radio frequency identification transponders, while rectal temperature and physiologic parameters (peripheral oxygen saturation, heart rate, respiratory rate) were recorded during maintenance. Recovery time was measured from isoflurane discontinuation until the first voluntary movement. The heated chamber reached thermal stability within 10 minutes; at steady state, a constant average surface temperature near 37.5 °C was reliably obtained. During induction, unheated controls showed a rapid decline in core temperature, while during the heated-chamber induction, they maintained normothermia. The control group did not regain baseline temperature until several minutes into the maintenance phase and stabilized at values ∼1 °C lower than those of the heated group. Both groups remained physiologically stable during anesthetic maintenance and recovered within comparable times. This cost-effective, Arduino-based chamber prevented early hypothermia without compromising physiologic stability and represents a practical refinement to improve rodent anesthetic procedures, animal welfare, and experimental reproducibility.

Indexed as

ABS, acrylonitrile-butadiene-styreneHR, heart rateNTC, negative temperature coefficientPID, proportional integral derivativeRFID, radio frequency identificationRR, respiratory rateSpO2, peripheral oxygen saturationΔT, temperature difference

Identifiers

PMID41620211
PMCPMC13086196

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.