ArticleFluids and barriers of the CNS2026
A novel method of fabricating dynamic, heterogenous benchtop lateral and third ventricle phantoms from MRI of hydrocephalus patients: a verification and validation study.
Article in Fluids and barriers of the CNS, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
backgroundInvestigation of the failure of shunts used to treat hydrocephalus has been a topic of research for several decades, though it is difficult to understand the role of heterogeneous patient ventriculomegaly shifts over time. In this work, we present the design, verification, and validation of a novel benchtop model of the human lateral and third ventricles.
methods3D models were rendered from MRI of pre-revision hydrocephalic patients (n = 6), printed in hollow High Impact Polystyrene (HIPS) molds, and injected with silicone rubber allowed to rotationally cure for three hours. Wall thickness of the ventricle models was measured via random point sampling (n = 300), assessing distribution of silicone rubber within the mold. One sample z-test was used to compare mean wall thickness to the target thickness of 1 mm. To visualize the inner volume post-hoc, expanding polyurethane foam was injected into ventricle models, creating negatives of the hollow molds. The negatives were 3D scanned and measured for frontal horn diameter, occipital horn diameter, Evan’s Index, Frontal-Occipital-Horn Ratio, and frontal horn volume. A single MRI was chosen for verification of repeatability (n = 11). Ventricular size was validated across models from patients (n = 6). Accuracy of ventricular expansion (indirect compliance assessment) was tested. For all tests, a confidence interval was set at 0.95 (α = 0.05).
resultsThe verification methods indicated that low variance of experimental clinical values were observed between ventricle model replicates. Nominal-actual comparison results consistently showed similar datapoint displacement densities between models. Validation showed that most ventricle geometries fell within 5% of MRI measurements. A strong positive correlation was observed between internal pressure and volume (R2 = 0.9932). Experimental Frontal Horn and Occipital Horn Diameter measurements compared to clinical observations showed anatomical accuracy.
conclusionThis study validates and verifies a model of the human ventricular system with arbitrarily chosen heterogeneous patient ventricles of varying morphologies and volumes. Paired with a pump, this model can be used to recapitulate cerebrospinal fluid flow. We show the recreation of patient-specific clinical lateral ventricle characteristics of size, shape, and static compliance control necessary to study the influence of these parameters on shunt function. The manufacturing process has the capacity to create accurate benchtop models of the lateral and third ventricles with geometric detail that should be refined over time with additive systems accounting for cranial viscoelastic compliance and varying material properties with elastic and shear moduli more similar to brain.