A novel method of fabricating dynamic, heterogenous benchtop lateral and third ventricle phantoms from MRI of hydrocephalus patients: a verification and validation study.

Blake Gura, Ahmad Faryami, Christopher Roberts, Carolyn A Harris

Abstract readValidation Study
In one paragraph

Article in Fluids and barriers of the CNS, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Blake GuraDepartment of Biomedical Engineering, Wayne State University, 818 W Hancock St, Detroit, MI, 48201, USA.
Ahmad FaryamiDepartment of Biomedical Engineering, Wayne State University, 818 W Hancock St, Detroit, MI, 48201, USA.
Christopher RobertsDepartmentof Chemical Engineering and Materials Science, Wayne State University, 5050 Anthony Wayne Dr, Detroit, MI, 48202, USA.
Carolyn A HarrisDepartment of Chemical Engineering and Materials Science, Wayne State University, 6135 Woodward Avenue, Rm 3120, Detroit, MI, 48202, USA. caharris@wayne.edu.

Funding

Investigating the source and the action behind shunt obstruction in the treatment of pediatric hydrocephalusR01NS094570 · NINDS · WAYNE STATE UNIVERSITY · PI Carolyn A Harris · 2016 to 2026
$4.2M
NIH HHS R01NS094570NINDS NIH HHS R01 NS094570
6 · The paper itself

Abstract

backgroundInvestigation of the failure of shunts used to treat hydrocephalus has been a topic of research for several decades, though it is difficult to understand the role of heterogeneous patient ventriculomegaly shifts over time. In this work, we present the design, verification, and validation of a novel benchtop model of the human lateral and third ventricles.

methods3D models were rendered from MRI of pre-revision hydrocephalic patients (n = 6), printed in hollow High Impact Polystyrene (HIPS) molds, and injected with silicone rubber allowed to rotationally cure for three hours. Wall thickness of the ventricle models was measured via random point sampling (n = 300), assessing distribution of silicone rubber within the mold. One sample z-test was used to compare mean wall thickness to the target thickness of 1 mm. To visualize the inner volume post-hoc, expanding polyurethane foam was injected into ventricle models, creating negatives of the hollow molds. The negatives were 3D scanned and measured for frontal horn diameter, occipital horn diameter, Evan’s Index, Frontal-Occipital-Horn Ratio, and frontal horn volume. A single MRI was chosen for verification of repeatability (n = 11). Ventricular size was validated across models from patients (n = 6). Accuracy of ventricular expansion (indirect compliance assessment) was tested. For all tests, a confidence interval was set at 0.95 (α = 0.05).

resultsThe verification methods indicated that low variance of experimental clinical values were observed between ventricle model replicates. Nominal-actual comparison results consistently showed similar datapoint displacement densities between models. Validation showed that most ventricle geometries fell within 5% of MRI measurements. A strong positive correlation was observed between internal pressure and volume (R2 = 0.9932). Experimental Frontal Horn and Occipital Horn Diameter measurements compared to clinical observations showed anatomical accuracy.

conclusionThis study validates and verifies a model of the human ventricular system with arbitrarily chosen heterogeneous patient ventricles of varying morphologies and volumes. Paired with a pump, this model can be used to recapitulate cerebrospinal fluid flow. We show the recreation of patient-specific clinical lateral ventricle characteristics of size, shape, and static compliance control necessary to study the influence of these parameters on shunt function. The manufacturing process has the capacity to create accurate benchtop models of the lateral and third ventricles with geometric detail that should be refined over time with additive systems accounting for cranial viscoelastic compliance and varying material properties with elastic and shear moduli more similar to brain.

Indexed as

HydrocephalusLateral VentriclesMagnetic Resonance ImagingModels, AnatomicPhantoms, ImagingThird VentricleHumansBenchtop modelHydrocephalusLateral and third ventriclesNominal-actual comparisonVentricle modelVentricle morphologyVentriculomegaly

Identifiers

PMID41618324
PMCPMC12860057

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.