Evidence map›Paper›PMID 41615089›Full record

ArticleMicrobiology spectrum2026

Comparative evaluation of two MALDI-TOF MS systems for microbial identification: accuracy and workflow efficiency in a clinical microbiology laboratory.

Jasmin Köffer, Jale Ören, Ulrike Betz, Janhendrik Timm, Meike Oftring, Nina Bauer, Maxime Ndolumingo, Lelia Abad, Ulrich Eigner

Abstract readComparative StudyEvaluation Study
In one paragraph

Article in Microbiology spectrum, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jasmin KöfferMVZ Laboratory Dr. Limbach, Heidelberg, Germany.
Jale ÖrenMVZ Laboratory Dr. Limbach, Heidelberg, Germany.
Ulrike BetzMVZ Laboratory Dr. Limbach, Heidelberg, Germany.
Janhendrik TimmbioMérieux, Marcy-l'Étoile, France.
Meike OftringbioMérieux, Marcy-l'Étoile, France.
Nina BauerbioMérieux, Marcy-l'Étoile, France.
Maxime NdolumingobioMérieux, Marcy-l'Étoile, France.
Lelia AbadbioMérieux, Marcy-l'Étoile, France.
Ulrich EignerMVZ Laboratory Dr. Limbach, Heidelberg, Germany.ORCID 0000-0002-0631-5105

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to compare the identification accuracy and workflow of the VITEK MS PRIME (VMP) and the MALDI Biotyper Sirius (BS) in a routine laboratory setting. A total of 927 isolates, representing 219 different species, were analyzed using both the VMP and the BS system. In addition, 119 positive blood cultures were tested after 4-6 h of subculture, with and without formic acid, and compared to the results obtained after 18 to 24 h. Hands-on time (HOT) and time to result (TTR) were measured based on a workflow consisting of 16 slides, each containing 16 isolates, with a total of 256 isolates, simulating the daily workload of a single technician. Of the 927 isolates tested, both systems demonstrated high identification rates (91.1% for BS and 95.5% for VMP). Agreement between the two matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) instruments after retesting was 99.4% and 97.5% at genus and species levels. In short-incubation cultures, VMP identified 118 (99.2%) isolates without and 113 (95.0%) with formic acid treatment, while BS identified 105 (88.2%) and 110 (92.4%), respectively. Workflow analysis demonstrated a HOT of 106 min and a TTR of 191 min for VMP with 252 successful identifications (98%). In contrast, BS required 155 min for both HOT and TTR, yielding 211 successful identifications (82%). Both MALDI-TOF systems evaluated in this study demonstrated an excellent concordance in the identification of a broad range of species. Depending on the laboratory settings, either system is well-suited to support an efficient and streamlined laboratory workflow. IMPORTANCE: This study provides a real-world comparison of two leading matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) systems, VITEK MS PRIME (VMP) and MALDI Biotyper Sirius (BS), based on 927 isolates across 219 species, including rare and challenging organisms. By simulating routine lab workflows working with several workstations, it offers practical insights into hands-on time and time to results. Unlike previous studies, it includes a broader sample set (including yeasts), evaluates short positive blood culture incubation conditions, and accounts for operator variability. These strengths make it a valuable resource for laboratories seeking evidence-based guidance on MALDI-TOF implementation and optimization.

Indexed as

BacteriaBacterial Typing TechniquesSpectrometry, Mass, Matrix-Assisted Laser Desorption-IonizationHumansLaboratories, ClinicalWorkflowMALDI Biotyper SiriusMALDI-TOF MSrapid identificationVITEK MS PRIMEworkflow

Identifiers

PMID41615089
PMCPMC12955377

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.