Evidence map›Paper›PMID 41614528›Full record

SynthesisEuropean stroke journal2026

Flow diverter treatment for saccular unruptured intracranial aneurysms: A systematic review focussing on study quality and initial outcomes.

Fabian Wenz, Tamara Wiedemann, Gabriel J E Rinkel, Nima Etminan

Abstract readSystematic Review
In one paragraph

Synthesis in European stroke journal, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Fabian WenzDepartment of Neurosurgery, University Hospital Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany.ORCID 0000-0002-2253-8376
Tamara WiedemannDepartment of Neurosurgery, University Hospital Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany.
Gabriel J E RinkelDepartment of Neurosurgery, University Hospital Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany.ORCID 0000-0001-8930-3953
Nima EtminanDepartment of Neurosurgery, University Hospital Mannheim, Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionFlow-diverting (FD) stents are increasingly used to treat small, unruptured intracranial aneurysms (UIA), but high-quality, unbiased data on initial complications and clinical outcomes were limited in previous literature reviews. We updated the literature review to assess quality, potential bias, complications and short-term outcomes in studies on FD-stents for UIAs. PATIENTS AND

methodsWe systematically searched PubMed, Embase and Cochrane Library until January 9, 2025 for studies on FD-stents for UIAs. We assessed methodological quality using the methodological index for non-randomised studies (poor: 0-9, moderate: 10-13, good: 14-16), and financial conflicts of interest. The primary outcome was neurological outcome according to a validated outcome scale at 1-3 months after treatment. Secondary outcomes were clinical worsening and complications.

resultsWe included 13 studies with 743 patients and 806 UIAs, of which 88.4% (95% CI: 85.7%-91.2%) were <10 mm. All studies were uncontrolled. The methodological quality was poor in six and moderate in seven studies. Financial conflicts of interest were reported in six studies. At 1-3 months after treatment, the proportion of patients were for mRS ⩾1 13.3% (95% CI: 10.0%-16.6%), mRS ⩾2 5.3% (95% CI: 3.2%-7.5%), mRS ⩾3 2.4% (95% CI: 0.1%-3.9%) and neurological worsening 3.1% (95% CI: 1.5%-4.6%). Complications within 3 months occurred in 12.7% (95% CI: 10.3%-15.0%). DISCUSSION AND

conclusionThe literature on FD-stents is methodologically weak and potentially biased by financial interests but still shows relevant proportions of complications and post-treatment morbidity. Currently, there are no good data supporting the use of FD-stents for UIAs where standard treatment options are available. Randomised-controlled trials are needed to compare safety, efficacy and durability between FD-stents and coiling or clipping.

Indexed as

Endovascular ProceduresIntracranial AneurysmStentsHumansTreatment OutcomeFlow-diverting stentsintracranial aneurysmsmall%unruptured

Identifiers

PMID41614528
PMCPMC12866275

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.