Evidence map›Paper›PMID 41613679›Full record

ReviewCureus2025

Comparative Safety and Efficacy of Left Atrial Appendage Occlusion Technologies for Prevention of Stroke and Bleeding in Atrial Fibrillation: A Comprehensive Meta-Analysis of Watchman Versus Oral Anticoagulation and Alternative Device Platforms.

Efe Opone, Nafees Khan, Sidra Jabeen

Abstract readReview
In one paragraph

Review in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Efe OponeInternal Medicine, University Hospitals Sussex, Brighton & Hove, GBR.
Nafees KhanInternal Medicine, University Hospitals Sussex, Brighton & Hove, GBR.
Sidra JabeenMedicine and Surgery, Liaquat National Hospital and Medical College, Karachi, PAK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Left atrial appendage occlusion (LAAO) offers an alternative to oral anticoagulation for stroke prevention in atrial fibrillation. We performed a systematic review and meta-analysis comparing Watchman (Boston Scientific Corporation, Marlborough, MA) with oral anticoagulants (OACs) and alternative LAAO devices. PubMed, EBSCO, and ClinicalTrials.gov were searched (January 2005 to August 2025) for randomised trials and observational studies comparing Watchman with OACs or other devices in adults with atrial fibrillation (minimum one-month follow-up). Twenty-one studies (eight randomised, 13 observational; n=12,357) were analysed. Results reflect combined randomised and observational evidence, with heterogeneity addressed using random-effects models. Most comparators were warfarin; DOAC-specific data were limited. Versus OACs, LAAO reduced transient ischaemic attack (odds ratio (OR) 0.72), haemorrhagic stroke (OR 0.41), all-cause mortality (OR 0.73), and cardiovascular mortality (OR 0.57), with similar ischaemic stroke rates (OR 1.09). Ten studies contributed device-device comparisons. Versus other devices, Watchman had fewer complications (OR 0.67) but more major peridevice leaks (OR 1.84). Watchman showed a consistently more favourable safety profile compared to others. Device-related complications were significantly lower (OR 0.67), including markedly reduced device embolisation (OR 0.45) and procedural bleeding (OR 0.68). Watchman also demonstrated fewer major procedural complications and a lower rate of pericardial effusion requiring intervention. Efficacy outcomes, including ischaemic stroke, transient ischaemic attack (TIA), haemorrhagic stroke, and systemic embolism, were comparable across devices, with no significant differences detected. Follow-up duration varied across studies, though absolute event rates remained low. Publication bias and residual confounding may influence mortality estimates, as device-generation reporting was incomplete. In conclusion, LAAO reduces haemorrhagic stroke and mortality compared with OACs while maintaining equivalent ischaemic stroke protection. Among devices, Watchman demonstrates superior procedural safety but increased leak rates.

Indexed as

anticoagulationatrial fibrillationbleedingleft atrial appendage occlusionmeta-analysismortalitystrokewatchman device

Identifiers

PMID41613679
PMCPMC12847066

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.