ArticleEmerging infectious diseases2026
Effect of Chloramine Disinfection of Community Water System on Legionnaires' Disease Outbreak, Minnesota, USA, 2024.
Article in Emerging infectious diseases, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
The Minnesota Department of Health identified an outbreak of Legionnaires' disease in a city in northern Minnesota, USA, in April 2023 that continued until chloramine disinfection of the community water system was implemented. Before chloramine disinfection was implemented, Legionella pneumophila was detected in 1 of 16 samples from the drinking water distribution system and in 5 of 10 premise plumbing samples using both cultivation-dependent (Legiolert) and cultivation-independent (digital PCR) assays in this independent investigation. Approximately 11 weeks after disinfection was implemented, all distribution system samples tested negative; however, 1 of 6 Legiolert-tested and 3 of 6 digital PCR-tested premise plumbing samples were positive. After 24 weeks of disinfection, all samples collected from the distribution system and premise plumbing tested negative. Our results show that a community water system supplied by groundwater supported substantial growth of L. pneumophila in premise plumbing and that chloramine disinfection halted the outbreak.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.