ArticleFluids and barriers of the CNS2026
Evaluation of shunt valve flow dynamics in series.
Article in Fluids and barriers of the CNS, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
- Erratum issued
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
background and purposeDysregulation of cerebrospinal fluid (CSF) volume results in hydrocephalus, a disease that leads to over 30,000 surgical shunt-valve implantations annually in the US. These shunt-valves require a trial-and-error process to determine optimal settings for each individual, sometimes resulting in implantation of multiple valves in series. This work sought to evaluate two mathematical models of the relationship between valve opening pressure settings in series and resultant drainage using a benchtop system to aid clinicians in determination of optimal shunt-valve settings.
methodsA gravity-driven in-vitro flow system at 37 °C with a simulated ICP of 22 cmH
resultsIn isolation, differential pressure and gravitational valves had low intra- and inter-valve variability (p > 0.05). Valves in series had highly variable flowrates across trials and sets of valves in both supine and upright positions (p < 0.05). Using calculated combined valve coefficients to predict flowrates of valves in series, the average percent error was 15 ± 7% and 23 ± 18% in the supine and upright positions, respectively.
conclusionsIn all, neither of the two models outperformed the other and both were insufficient to properly characterize the relationship between drainage and opening pressures of valves in series. These results indicate low flowrate variability of isolated valves but high variability of valves placed in series. Without a consistent model from which opening pressure setting of valves in series can be determined, physicians must rely on a trial-and-error method in optimal opening pressure determination which directly impacts patient outcomes. These findings underscore the difficulties faced by physicians in determination of optimal valve settings for shunted patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.