Evidence map›Paper›PMID 41612416›Full record

ArticleJournal of orthopaedic surgery and research2026

Progressive wear divergence beyond 10 years in ceramic- vs. metal-on-polyethylene bearings: the 25-year impact of zirconia degradation in total hip arthroplasty.

Tsunehito Ishida, Yasuhito Takahashi, Toshiyuki Tateiwa, Toshinori Masaoka, Takaaki Shishido, Takeshi Seki, Kengo Yamamoto

Abstract readComparative Study
In one paragraph

Article in Journal of orthopaedic surgery and research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Tsunehito IshidaDepartment of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan. tsune725@aol.com.
Yasuhito TakahashiDepartment of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan. yasuhito@tokyo-med.ac.jp.
Toshiyuki TateiwaDepartment of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan.
Toshinori MasaokaDepartment of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan.
Takaaki ShishidoDepartment of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan.
Takeshi SekiDepartment of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan.
Kengo YamamotoDepartment of Orthopedic Surgery, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjuku-ku, Tokyo, 160-0023, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis study aimed to compare the long-term polyethylene wear in total hip arthroplasty (THA) using ceramic-on-polyethylene (CoP) bearings with monolithic zirconia femoral heads versus metal-on-polyethylene (MoP) bearings with cobalt-chromium heads. A secondary objective was to assess the in vivo impact of zirconia low-temperature degradation (LTD) on polyethylene wear.

methodsSixty-two hips were assigned to two demographically matched cohorts receiving polyethylene liners paired with either 28-mm monolithic zirconia or cobalt-chromium heads. All patients received the same implant design and were followed for a minimum of 20 years. Linear head penetration was evaluated over a 25-year period. A zirconia head retrieved after 25 years was analyzed via Raman spectroscopy to investigate phase transformation and residual stress.

resultsDuring the first 10 years post-THA, no significant differences were observed in cumulative polyethylene wear or linear wear rates between the MoP and CoP groups. However, beyond 10 years, these groups demonstrated differing wear patterns, with wear tending to increase in the CoP group and decrease in the MoP group. Between 10 and 25 years, the wear rate in the CoP group was approximately 2.4 times higher than that in the MoP group. Analysis of the retrieved zirconia head revealed extensive monoclinic phase transformation (92.3%), high compressive residual stress (- 1.9 GPa), and notable grain uplift, correlating with an elevated wear rate of 0.212 mm/year during the second decade.

conclusionsMoP and CoP bearings demonstrated similar polyethylene wear characteristics during the first decade after THA. However, a marked divergence emerged in the second decade, with significantly higher wear rates observed in the CoP group, likely attributable to the accelerated progression of zirconia LTD. These findings highlight the long-term implications of ceramic degradation and emphasize the need for careful evaluation of zirconia-based components in THA regarding their durability over time.

Indexed as

Arthroplasty, Replacement, HipCeramicsHip ProsthesisPolyethyleneProsthesis DesignProsthesis FailureZirconiumAgedFemaleFollow-Up StudiesHumansMaleMiddle AgedTime FactorsPolyethyleneZirconiumzirconium oxideCeramic-on-polyethyleneMetal-on-polyethylenePolyethylene wearTotal hip arthroplastyZirconia low-temperature degradation

Identifiers

PMID41612416
PMCPMC12924471

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.