Evidence map›Paper›PMID 41612408›Full record

ArticleBMC veterinary research2026

Does the bone drill bit remain sharp after a collision with the intramedullary pin? a study on isolated canine tibias.

Piotr Trębacz, Michał Czopowicz, Magdalena Antonowicz-Hüpsch, Karolina Wilk, Anna Barteczko, Mateusz Pawlik, Agata Piątek, Aleksandra Kurkowska

Abstract read
In one paragraph

Article in BMC veterinary research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Piotr TrębaczDepartment of Surgery and Anaesthesiology of Small Animals, Institute of Veterinary Medicine, Warsaw University of Life Sciences-SGGW, Nowoursynowska 159 C, Warsaw, 02-776, Poland. piotr_trebacz@sggw.edu.pl.
Michał CzopowiczDivision of Veterinary Epidemiology and Economics, Institute of Veterinary Medicine, Warsaw University of Life Sciences-SGGW, Nowoursynowska 159 C, Warsaw, 02- 776, Poland.
Magdalena Antonowicz-HüpschDepartment of Biomaterials and Medical Devices Engineering, Faculty of Biomedical Engineering, Silesian University of Technology, Roosevelta 40, Zabrze, 41-800, Poland.
Karolina WilkDepartment of Biomaterials and Medical Devices Engineering, Faculty of Biomedical Engineering, Silesian University of Technology, Roosevelta 40, Zabrze, 41-800, Poland.
Anna BarteczkoCABIOMEDE Ltd, Karola Olszewskiego 21, Kielce, 25-663, Poland.
Mateusz PawlikDepartment of Biomaterials and Medical Devices Engineering, Faculty of Biomedical Engineering, Silesian University of Technology, Roosevelta 40, Zabrze, 41-800, Poland.
Agata PiątekDepartment of Biomaterials and Medical Devices Engineering, Faculty of Biomedical Engineering, Silesian University of Technology, Roosevelta 40, Zabrze, 41-800, Poland.
Aleksandra KurkowskaDepartment of Biomaterials and Medical Devices Engineering, Faculty of Biomedical Engineering, Silesian University of Technology, Roosevelta 40, Zabrze, 41-800, Poland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundBlunting of the tip, as well as smoothing and abrasion of the cutting edges, are natural signs of wear observed under magnification after repeated use of bone drill bits. The lack of a standardized surgical protocol for using drill bits in human and veterinary surgery often results in their use beyond the manufacturer’s recommended limits. Drilling with a dull drill bit results in excessive local material degradation, increased surface roughness, and inaccurate hole dimensions. In bone surgery, an additional factor is thermal damage to the bone. Colliding with a metallic object while rotating can cause the cutting edges of the drill bit to become blunt or chipped, or the drill bit to bend or break. This study aimed to analyze damage to bone drill bits resulting from collisions with an intramedullary Kirschner wire.

methodsThe experiment was performed on the left and right isolated tibias of an adult female Boxer dog. Kirschner wires were inserted intramedullary, and holes were drilled in mediolateral and craniocaudal directions to mimic plate-rod osteosynthesis. The drill bits were evaluated for suitability for repeated use based on an examination using a binocular stereomicroscope and digital microscope.

resultsOne bone drill bit broke. Only 17 / 44 unbroken bone drill bits (39%) could be reused following collision with the Kirschner wire. Twenty-seven drill bits sustained significant damage to their main cutting edges and were deemed unsuitable for reuse.

conclusionsContact between the rotating drill bit and the intramedullary implant is undesirable. If this occurs, the drill bit should be examined under a microscope to determine its suitability for further use.

Indexed as

Bone NailsFracture Fixation, IntramedullarySurgical InstrumentsTibiaAnimalsBone WiresDogsFemaleBone drillingBone surgeryDull drill bitOrthopedic instrumentsSmall animalsSurgical tool durabilityVeterinary orthopedics

Identifiers

PMID41612408
PMCPMC12930961

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.