Evidence map›Paper›PMID 41611820›Full record

ArticleEuropean journal of nuclear medicine and molecular imaging2026

SPECT/CT peak tracer uptake is a strong predictor of aseptic loosening in painful total knee arthroplasty.

Helmut Rasch, Randa Elsheikh, George M Avram, Alexandra Leica, Sabrina Chelli, Felix Amsler, Andrej M Nowakowski, Rolf Huegli, Michael T Hirschmann

Abstract read
In one paragraph

Article in European journal of nuclear medicine and molecular imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Helmut Rasch *Institute of Radiology and Nuclear Medicine, Kantonsspital Baselland, Bruderholz, CH-4101, Switzerland.
Randa Elsheikh *University Department of Orthopedic Surgery and Traumatology, Kantonsspital Baselland, Bruderholz, CH-4101, Switzerland.
George M AvramUniversity Department of Orthopedic Surgery and Traumatology, Kantonsspital Baselland, Bruderholz, CH-4101, Switzerland.
Alexandra LeicaUniversity Department of Orthopedic Surgery and Traumatology, Kantonsspital Baselland, Bruderholz, CH-4101, Switzerland.
Sabrina ChelliUniversity Department of Orthopedic Surgery and Traumatology, Kantonsspital Baselland, Bruderholz, CH-4101, Switzerland.
Felix AmslerAmsler Consulting, Basel, Switzerland.
Andrej M NowakowskiUniversity Department of Orthopedic Surgery and Traumatology, Kantonsspital Baselland, Bruderholz, CH-4101, Switzerland.
Rolf HuegliInstitute of Radiology and Nuclear Medicine, Kantonsspital Baselland, Bruderholz, CH-4101, Switzerland.
Michael T HirschmannUniversity Department of Orthopedic Surgery and Traumatology, Kantonsspital Baselland, Bruderholz, CH-4101, Switzerland. michael.hirschmann@unibas.ch.ORCID http://orcid.org/0000-0002-4014-424X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aims to evaluate the diagnostic accuracy of quantitative three-dimensional Single-Photon Emission Computed Tomography (SPECT/CT) analysis for detecting aseptic loosening after total knee arthroplasty (TKA) and to establish component-specific quantitative thresholds.

methodsIn this retrospective cohort study, patients with painful TKA who underwent standardized assessment, including SPECT/CT after the exclusion of infection, were analyzed. Imaging was performed on a Symbia Intevo Bold (Siemens) and reconstructed using the xSPECT Quant algorithm. Component-specific volumetric uptake parameters, including Maximum, Peak, Mean, and Metabolic Volume, were quantified. Stepwise logistic regression was applied to identify the parameter with the highest diagnostic performance. Optimal cutoff values were established using the Youden Index and the Closest Top method.

resultsOf 107 screened patients, 86 were included in the final analysis. Intraoperative findings confirmed component loosening in 25 cases. Peak uptake showed the highest diagnostic performance for both femoral and tibial components. For femoral loosening, a Peak uptake threshold of 77.2 kBq/ml provided the most balanced diagnostic performance, yielding a sensitivity of 70.6%, specificity of 66.7%, and a negative predictive value (NPV) of 90.2%. For tibial loosening, a threshold of 89.5 kBq/ml achieved a sensitivity of 72.7%, specificity of 80%, and an NPV of 95.2%. The area under the curve was 0.87 for tibial loosening and 0.80 for femoral loosening.

conclusionQuantitative SPECT/CT using Peak uptake analysis enables objective and reproducible diagnosis of aseptic loosening. The identified component-specific thresholds show strong predictive value, though the diagnostic accuracy was lower for the femoral component, emphasizing the need for individualized assessment and further prospective validation.

Indexed as

Arthroplasty, Replacement, KneeProsthesis FailureSingle Photon Emission Computed Tomography Computed TomographyAgedBiological TransportFemaleHumansMaleMiddle AgedRetrospective StudiesAseptic looseningFemur peakKnee arthroplastySPECT/CTTibia peakTracer uptake

Identifiers

PMID41611820
PMCPMC13649804

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.