ArticleEuropean journal of nuclear medicine and molecular imaging2026
SPECT/CT peak tracer uptake is a strong predictor of aseptic loosening in painful total knee arthroplasty.
Article in European journal of nuclear medicine and molecular imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThis study aims to evaluate the diagnostic accuracy of quantitative three-dimensional Single-Photon Emission Computed Tomography (SPECT/CT) analysis for detecting aseptic loosening after total knee arthroplasty (TKA) and to establish component-specific quantitative thresholds.
methodsIn this retrospective cohort study, patients with painful TKA who underwent standardized assessment, including SPECT/CT after the exclusion of infection, were analyzed. Imaging was performed on a Symbia Intevo Bold (Siemens) and reconstructed using the xSPECT Quant algorithm. Component-specific volumetric uptake parameters, including Maximum, Peak, Mean, and Metabolic Volume, were quantified. Stepwise logistic regression was applied to identify the parameter with the highest diagnostic performance. Optimal cutoff values were established using the Youden Index and the Closest Top method.
resultsOf 107 screened patients, 86 were included in the final analysis. Intraoperative findings confirmed component loosening in 25 cases. Peak uptake showed the highest diagnostic performance for both femoral and tibial components. For femoral loosening, a Peak uptake threshold of 77.2 kBq/ml provided the most balanced diagnostic performance, yielding a sensitivity of 70.6%, specificity of 66.7%, and a negative predictive value (NPV) of 90.2%. For tibial loosening, a threshold of 89.5 kBq/ml achieved a sensitivity of 72.7%, specificity of 80%, and an NPV of 95.2%. The area under the curve was 0.87 for tibial loosening and 0.80 for femoral loosening.
conclusionQuantitative SPECT/CT using Peak uptake analysis enables objective and reproducible diagnosis of aseptic loosening. The identified component-specific thresholds show strong predictive value, though the diagnostic accuracy was lower for the femoral component, emphasizing the need for individualized assessment and further prospective validation.