Evidence map›Paper›PMID 41607135›Full record

ArticleEuropace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology2026

Validation of the PADIT (prevention of arrhythmia device infection trial) risk score for infection and infection subtypes.

Mehrdad Golian, Zhe Li, Nicolas M Berbenetz, Roupen Odabashian, Mouhannad M Sadek, Vicente Corrales-Medina, Alper Aydin, Darryl R Davis, Martin S Green, Andres Klein and 8 more

Abstract readValidation Study
In one paragraph

Article in Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

18 authors.

Mehrdad GolianDivision of Cardiology, Department of Medicine, University of Ottawa and University of Ottawa Heart Institute, H-1285D, 40 Ruskin St. Ottawa, Ottawa Ontario K1Y 4W7, Canada.ORCID 0000-0003-2838-5355
Zhe LiDivision of Cardiology, Department of Medicine, University of Ottawa and University of Ottawa Heart Institute, H-1285D, 40 Ruskin St. Ottawa, Ottawa Ontario K1Y 4W7, Canada.ORCID 0000-0001-7856-2431
Nicolas M BerbenetzDivision of Cardiology, Department of Medicine, University of Ottawa and University of Ottawa Heart Institute, H-1285D, 40 Ruskin St. Ottawa, Ottawa Ontario K1Y 4W7, Canada.ORCID 0000-0003-4260-6556
Roupen OdabashianDivision of Cardiology, Department of Medicine, University of Ottawa and University of Ottawa Heart Institute, H-1285D, 40 Ruskin St. Ottawa, Ottawa Ontario K1Y 4W7, Canada.ORCID 0009-0003-9276-3055
Mouhannad M SadekDivision of Cardiology, Department of Medicine, University of Ottawa and University of Ottawa Heart Institute, H-1285D, 40 Ruskin St. Ottawa, Ottawa Ontario K1Y 4W7, Canada.ORCID 0000-0003-2526-9359
Vicente Corrales-MedinaDivision of Infectious Diseases, Department of Medicine, University of Ottawa and the Ottawa Hospital, Ottawa, Ontario, Canada.ORCID 0000-0002-9691-491X
Alper AydinDivision of Cardiology, Department of Medicine, University of Ottawa and University of Ottawa Heart Institute, H-1285D, 40 Ruskin St. Ottawa, Ottawa Ontario K1Y 4W7, Canada.ORCID 0000-0003-1578-0858
Darryl R DavisDivision of Cardiology, Department of Medicine, University of Ottawa and University of Ottawa Heart Institute, H-1285D, 40 Ruskin St. Ottawa, Ottawa Ontario K1Y 4W7, Canada.ORCID 0000-0001-9642-3910
Martin S GreenDivision of Cardiology, Department of Medicine, University of Ottawa and University of Ottawa Heart Institute, H-1285D, 40 Ruskin St. Ottawa, Ottawa Ontario K1Y 4W7, Canada.
Andres KleinDivision of Cardiology, Department of Medicine, University of Ottawa and University of Ottawa Heart Institute, H-1285D, 40 Ruskin St. Ottawa, Ottawa Ontario K1Y 4W7, Canada.ORCID 0000-0001-7395-7338
Girish M NairDivision of Cardiology, Department of Medicine, University of Ottawa and University of Ottawa Heart Institute, H-1285D, 40 Ruskin St. Ottawa, Ottawa Ontario K1Y 4W7, Canada.ORCID 0000-0002-3303-1490
Pablo B NeryDivision of Cardiology, Department of Medicine, University of Ottawa and University of Ottawa Heart Institute, H-1285D, 40 Ruskin St. Ottawa, Ottawa Ontario K1Y 4W7, Canada.ORCID 0000-0001-7482-8474
F Daniel RamirezDivision of Cardiology, Department of Medicine, University of Ottawa and University of Ottawa Heart Institute, H-1285D, 40 Ruskin St. Ottawa, Ottawa Ontario K1Y 4W7, Canada.ORCID 0000-0002-4350-1652
Calum RedpathDivision of Cardiology, Department of Medicine, University of Ottawa and University of Ottawa Heart Institute, H-1285D, 40 Ruskin St. Ottawa, Ottawa Ontario K1Y 4W7, Canada.ORCID 0000-0003-2137-3896
Simon P HansomDivision of Cardiology, Department of Medicine, University of Ottawa and University of Ottawa Heart Institute, H-1285D, 40 Ruskin St. Ottawa, Ottawa Ontario K1Y 4W7, Canada.ORCID 0000-0003-2767-6433
Jodi D EdwardsDivision of Cardiology, Department of Medicine, University of Ottawa and University of Ottawa Heart Institute, H-1285D, 40 Ruskin St. Ottawa, Ottawa Ontario K1Y 4W7, Canada.
Andrew D KrahnDivision of Cardiology, Department of Medicine, University of British Columbia, Vancouver, BC, Canada.ORCID 0000-0002-7982-1586
David H BirnieDivision of Cardiology, Department of Medicine, University of Ottawa and University of Ottawa Heart Institute, H-1285D, 40 Ruskin St. Ottawa, Ottawa Ontario K1Y 4W7, Canada.ORCID 0000-0001-6495-1428

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimsCardiac implantable electronic device (CIED) infection carries a substantial burden of morbidity, mortality, and cost. The Prevention of Arrhythmia Device Infection Trial (PADIT) risk score improves identification of high-risk patients and may guide targeted strategies to reduce infection. Recent work has categorized CIED infection into localized pocket vs. systemic infection, with early reports suggesting different risk factors for each. However, no current risk score has been validated for infection subtypes.ObjectivesIndependently validate the PADIT infection risk score.Compare risk factors for infection subtypes.Assess PADIT performance in predicting subtype-specific infection. METHODS AND

resultsA prospective registry was initiated at the University of Ottawa Heart Institute in 2007 to capture all CIED procedures and prospectively identify infections in collaboration with the infection prevention team. PADIT risk score components were documented for each procedure. All suspected infections were adjudicated independently by two physicians (with a third if required), blinded to PADIT score and baseline variables, and subclassified as pocket or systemic infection. Logistic regression models were generated to validate PADIT performance for each subtype, with evaluation using Akaike and Bayesian information criteria (AIC/BIC), C-statistics, and calibration slope. Between 2007 and 2020, 14,225 procedures were performed (mean age 72 ± 14 years, 35% female, 70% new implants, 18% generator changes, 11% upgrades). A total of 103 infections (0.73%) were adjudicated, of which 71 (69%) were pocket and 32 (31%) systemic. The PADIT score showed good predictive performance with a C-statistic of 0.687 (95% CI 0.655-0.743), similar to the derivation cohort (0.702, 95% CI 0.661-0.741). Notably, the number of prior procedures was strongly associated with pocket infection but not systemic infection. PADIT discrimination was consistent across subtypes: pocket infection C-statistic 0.691 (95% CI 0.649-0.761) and systemic infection 0.746 (95% CI 0.707-0.848). Calibration slopes demonstrated good agreement between predicted and observed events, with the best fit for systemic infection.

conclusionThe PADIT score was independently validated with discrimination and calibration similar to the original derivation cohort. Importantly, prior procedures predicted pocket but not systemic infection. Overall, PADIT performed well in predicting both subtypes, with the strongest model fit observed for systemic infection.

Indexed as

Arrhythmias, CardiacDefibrillators, ImplantablePacemaker, ArtificialProsthesis-Related InfectionsAgedAged, 80 and overFemaleHumansMalePredictive Value of TestsProspective StudiesRegistriesReproducibility of ResultsRisk AssessmentRisk FactorsAntibioticsbull PacemakerCardiac implantable electronic deviceComplicationDevice upgradeImplantable cardioverter defibrillatorInfectionPADITPulse generator changeRisk score

Identifiers

PMID41607135
PMCPMC12910619

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.