Evidence map›Paper›PMID 41606456›Full record

ArticleBMC bioinformatics2026

MIMI: Molecular Isotope Mass Identifier for stable isotope-labeled Fourier transform ultra-high mass resolution data analysis.

Nabil Rahiman, Michael A Ochsenkühn, Shady A Amin, Kristin C Gunsalus

Abstract read
In one paragraph

Article in BMC bioinformatics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Nabil Rahiman *Center for Genomics and System Biology, New York University Abu Dhabi, Abu Dhabi, United Arab Emirates.
Michael A Ochsenkühn *Marine Microbiomics Lab, Division of Biology, NYU Abu Dhabi, New York University, Abu Dhabi, United Arab Emirates.
Shady A AminCenter for Genomics and System Biology, New York University Abu Dhabi, Abu Dhabi, United Arab Emirates. sa132@nyu.edu.
Kristin C GunsalusCenter for Genomics and System Biology, New York University Abu Dhabi, Abu Dhabi, United Arab Emirates. kcg1@nyu.edu.

Funding

Gordon and Betty Moore Foundation award to SAA GBMF9335NYU Abu Dhabi award to SAA AD179Tamkeen under the NYU Abu Dhabi Research Institute Award for the NYUAD Center for Genomics and Systems Biology to KCG and SAA ADHPG-CGSB
6 · The paper itself

Abstract

backgroundUltra High Resolution (UHR) mass spectrometry systems with Fourier Transform Ion Cyclotron Resonance (FT-ICR) are often used to analyze the composition of complex mixtures of naturally-occurring or isotopically-enriched small molecules, such as metabolite samples for environmental, biological, or paleontological studies. The extremely high resolution of these systems enables simultaneous measurement of the exact masses of tens of thousands of molecular features and accurate determination of chemical formulas based on isotopic fine-structure ratios. To accelerate and streamline analysis of these datasets, automated solutions to rapidly characterize the molecular composition of unknown samples by comparison with known reference databases are needed.

resultsHere we present Molecular Isotope Mass Identifier (MIMI), a commandline tool to identify molecules present in complex samples using data from UHR-FT-ICR mass spectrometry. Given a database of known molecules and expected ratios of atomic isotopes in the sample, MIMI first computes theoretical exact masses and expected abundance for all possible isotopic variants in the database. Chemical formulas from publicly available databases and/or custom lists of molecules of interest can be used as reference data for comparison. By default MIMI is configured to use natural isotopic abundances, but its advantage is it can easily accommodate different user-defined isotopic labeling ratios for any element(s). Candidate molecules are first identified in peak lists from UHR-FT-ICR mass spectrometry runs by comparing masses detected in the experimental data with precomputed theoretical masses for all entries in the reference database. Chemical formulas are then verified by counting isotopic fine-structure matches with the theoretical values for all possible molecular isotopic variants and can be further validated by comparing observed vs. expected relative peak heights. We illustrate MIMI’s utility using metabolite data from a cultured diatom sample isolated from seawater in the Arabian Gulf and spiked with 13C-labeled internal standards, as well as a sample containing naturally-abundant metabolite standards.

conclusionsWe introduce a simple commandline tool, MIMI, that rapidly identifies chemicals present in samples of complex composition using UHR-FT-ICR mass spectrometry data. MIMI can compare measured data against both standard and customized molecular databases and can accommodate natural or user-specified isotope ratios. This software provides a convenient tool for simultaneous determination of natural and isotope-labeled compounds within the same sample, particularly for rapid characterization of complex mixtures of metabolites.

Indexed as

Fourier AnalysisIsotope LabelingMass SpectrometrySoftwareMolecular WeightFT-ICRIsotope labelingMass spectrometryMetabolomics

Identifiers

PMID41606456
PMCPMC12879430

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.