Evidence map›Paper›PMID 41604134›Full record

ArticleRadiological physics and technology2026

Regional mammography dosimetry in South India: establishing modality and thickness-specific diagnostic reference levels.

Adhimoolam Saravana Kumar, Sudhir Kumar, Renato Padovani, Thangavel Manojkumar, K N Govindarajan, Balvinder Kaur Sapra

Abstract read
PubMed Publisher
In one paragraph

Article in Radiological physics and technology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Adhimoolam Saravana KumarDepartment of Medical Physics, PSG Institute of Medical Sciences Research & Hospitals, Coimbatore, Tamil Nadu, 641 004, India. sarava87@gmail.com.ORCID http://orcid.org/0000-0001-5423-3406
Sudhir KumarRadiological Physics and Advisory Division, Bhabha Atomic Research Centre (BARC), CT&CRS, Anushaktinagar, Mumbai, 400 094, India.
Renato PadovaniMedical Physics Section, International Centre for Theoretical Physics, Trieste, Italy.
Thangavel ManojkumarDepartment of Medical Physics, PSG Institute of Medical Sciences Research & Hospitals, Coimbatore, Tamil Nadu, 641 004, India.
K N GovindarajanDepartment of Medical Physics, PSG Institute of Medical Sciences Research & Hospitals, Coimbatore, Tamil Nadu, 641 004, India.
Balvinder Kaur SapraRadiological Physics and Advisory Division, Bhabha Atomic Research Centre (BARC), CT&CRS, Anushaktinagar, Mumbai, 400 094, India.

Funding

Board of Research in Nuclear Sciences Sanction No: 54/14/01/2023BRNS/11432
6 · The paper itself

Abstract

backgroundThe mean glandular dose (MGD) is the key indicator for assessing radiation risk in mammography. International bodies such as the ICRP and IAEA recommend diagnostic reference levels (DRLs) to support optimization, yet India lacks national benchmarks. This study reports the first multicenter dosimetric survey in Tamil Nadu to derive modality- and thickness-specific DRLs.

methodsFrom 2023 to 2025, 100 mammography units (70 CR, 20 DR, 10 DBT) across public and private facilities were evaluated. Entrance surface air kerma (ESAK), half-value layer (HVL), and compression force were measured on 30–90 mm PMMA phantoms using a calibrated solidstate detector and a parallel-plate ionization chamber. MGD was calculated with the Dance model, and 75th percentile values were adopted as DRLs following ICRP 135. Inter-detector agreement was assessed by percentage difference.

resultsMGD increased with phantom thickness. Ion chamber-based DRLs ranged from 0.8 to 4.0 mGy for CR, 0.7–3.9 mGy for DR, and 1.3–4.5 mGy for DBT. DR demonstrated superior dose efficiency compared with CR, while DBT produced higher values due to tomographic acquisitions. Agreement between detectors was excellent (≤ 3%), validating solid-state use for large-scale surveys. Tamil Nadu DRLs were comparable to or lower than UK, Irish, and Australian values and remained well below the U.S. MQSA regulatory threshold.

conclusionThis survey establishes the first regional ion-chamber–based DRLs for mammography in India. The findings align with international standards, provide a framework for clinical dose optimization, and form the basis for national DRL development.

Indexed as

MammographyRadiometryDiagnostic Reference LevelsHumansIndiaPhantoms, ImagingRadiation DosageDiagnostic reference levelsDosimetryMean glandular doseParallel plate ionization chamberSolid-state detector

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.