Evidence map›Paper›PMID 41603582›Full record

ArticleJournal of biomechanical engineering2026

Intrinsic Viscoelasticity of Type II Collagen Contributes to the Viscoelastic Response of Immature Bovine Articular Cartilage Under Unconfined Compression Stress Relaxation.

Kimberly R Kroupa, Raphael Kepecs, Haoyu Zhang, Jeffrey A Weiss, Clark T Hung, Gerard A Ateshian

Abstract read
In one paragraph

Article in Journal of biomechanical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kimberly R KroupaDepartment of Mechanical Engineering, Columbia University, New York, 10027.
Raphael KepecsDepartment of Mechanical Engineering, Columbia University, New York, 10027.
Haoyu ZhangDepartment of Mechanical Engineering, Columbia University, New York, 10027.
Jeffrey A WeissDepartment of Biomedical Engineering, University of Utah, Salt Lake City, UT 84112;Department of Orthopaedic Surgery, University of Utah, Salt Lake City, UT 84112.ORCID 0000-0002-7264-2454
Clark T HungDepartment of Biomedical Engineering, Columbia University, New York, 10027.
Gerard A AteshianDepartment of Mechanical Engineering, Columbia University, New York, 10027;Department of Biomedical Engineering, Columbia University, New York, 10027.

Funding

Finite Elements For Biomechanics And BiophysicsR01GM083925 · NIGMS · UTAH STATE HIGHER EDUCATION SYSTEM--UNIVERSITY OF UTAH · PI GERARD A. ATESHIAN, JEFFREY A. WEISS · 2008 to 2026
$7.6M
NIGMS NIH HHS R01 GM083925NIGMS NIH HHS R01GM083925
6 · The paper itself

Abstract

Cartilage damage under loading is significantly affected by viscoelasticity. This study validates a finite deformation, nonlinear viscoelastic constitutive model for the collagen matrix of immature bovine articular cartilage, using reactive viscoelasticity. To examine the flow-independent viscoelasticity of cartilage collagen, tissue samples underwent proteoglycan (PG) digestion, losing more than 98% of their initial PG content to increase their hydraulic permeability. To verify that this PG-digestion eliminated flow-dependent viscoelasticity, PG-depleted samples were subjected to a gravitational permeation experiment, demonstrating that their hydraulic permeability, k=268 ± 152 mm4/N⋅s (n = 8), was five orders of magnitude greater than reported for untreated cartilage, confirming negligible flow-dependent viscoelasticity. Digested cartilage plugs were then subjected to unconfined compression stress relaxation (four consecutive ramp-hold profiles, each increasing the compressive strain by 10%) to fit the load response and extract material properties (RMSEfit=1.86 ± 0.61 kPa, n = 8). Successful curve-fitting served as a necessary condition for validating the model. Then, a separate unconfined compression stress-relaxation test was performed on the same samples, to 40% compressive strain at the same ramp rate. The model was able to faithfully predict this experimental response using fitted material properties (RMSEpred=3.95 ± 1.33 kPa, with 0≤ stresses ≤ 155 ± 37 kPa), providing a sufficient condition for validation in unconfined compression stress-relaxation. A computational model then showed that flow-independent viscoelasticity of cartilage collagen can enhance the stress response by ∼15% at fast strain rates, over flow-dependent effects. However, we estimate from prior studies that flow-independent viscoelasticity may enhance the stress response of cartilage by up to 200%, implying that PGs probably contribute significantly to the tissue's flow-independent viscoelasticity.

Indexed as

Cartilage, ArticularCollagen Type IICompressive StrengthElasticityStress, MechanicalAnimalsCattleProteoglycansViscosityCollagen Type IIProteoglycans

Identifiers

PMID41603582
PMCPMC13232614

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.