Evidence map›Paper›PMID 41603462›Full record

ArticleSICOT-J2026

Direction of screw insertion for internal fixation plate in distal femoral osteotomy: Evaluation using axial computer tomography imaging.

Fumiyoshi Kawashima, Ryuichi Nakamura, Akira Okano, Kaori Matsumoto, Jun Oike, Koji Kanzaki

Abstract read
In one paragraph

Article in SICOT-J, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Fumiyoshi KawashimaDepartment of Orthopaedic Surgery, Showa Medical University Fujigaoka Hospital, 1-30 Fujigaoka, Aoba Ward, Yokohama, Kanagawa 227-8501, Japan - Joint Preservation and Sports Orthopaedics Center, Harue Hospital, 65-7 Haruecho Haribara, Sakai, Fukui 919-0476, Japan.ORCID 0000-0002-0179-3685
Ryuichi NakamuraJoint Preservation and Sports Orthopaedics Center, Harue Hospital, 65-7 Haruecho Haribara, Sakai, Fukui 919-0476, Japan.ORCID 0000-0002-1743-7749
Akira OkanoJoint Preservation and Sports Orthopaedics Center, Harue Hospital, 65-7 Haruecho Haribara, Sakai, Fukui 919-0476, Japan.
Kaori MatsumotoJoint Preservation and Sports Orthopaedics Center, Harue Hospital, 65-7 Haruecho Haribara, Sakai, Fukui 919-0476, Japan.
Jun OikeDepartment of Orthopaedic Surgery, Showa Medical University Fujigaoka Hospital, 1-30 Fujigaoka, Aoba Ward, Yokohama, Kanagawa 227-8501, Japan.
Koji KanzakiDepartment of Orthopaedic Surgery, Showa Medical University Fujigaoka Hospital, 1-30 Fujigaoka, Aoba Ward, Yokohama, Kanagawa 227-8501, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeIn distal femoral osteotomy (DFO), using longer distal screws in fixation plates may improve stability. This study examined the insertion direction of three distal screws at the horizontal cross-section to determine if posterior angulation enables deeper placement.

methodsForty-seven varus knees that underwent DFO were included (medial closed-wedge DFO [MCWDFO], 30 knees; lateral closed-wedge DFO [LCWDFO], 17 knees). Postoperative plain CT images were obtained from a plane parallel to the three distal screws, with the most distal screw designated as A, the anterior of the second distal row as B, and the posterior of the second distal row as C. For each case, a curve passing through the center of the bony cortex on the cross-section parallel to each screw and over its entire length was drawn, and the curve and the lower edge of the screw were projected onto a graph. The maximum angle at which the lower edge of each screw touches the intercondylar region without interfering with the intercondylar region was designated as (AnA), (AnB), and (AnC) for A-, B-, and C-screws, respectively. The angle between the line connecting the insertion points of the B- and C-screws on the plate and the tangent line to the medial and lateral bony cortex was designated as (AnP).

resultsIn the MCWDFO group, the mean values for each parameter were AnA, 10.9 ± 5.4; AnB, 27.0 ± 4.2; AnC, 9.2 ± 3.4; and AnP, -2.6 ± 6.9. In the LCWDFO group, the mean values for each parameter were AnA, 18.2 ± 6.9; AnB, 30.4 ± 7.1; AnC, 16.1 ± 7.2; AnP, -0.2 ± 6.1°.

conclusionsThe medial surface is inclined compared to the epicondylar axis and posterior condyle, usually resulting in plate positioning that is parallel to the placement surface. The optimal screw insertion from the anterior to posterior was generally achieved; however, there was still room for posterior angulation margins of 9-11° for A- and C-screws and approximately 27° for the B-screw. In contrast, the lateral surface is flatter with less inclination, causing anterior plate placement and wider posterior angulation - approximately 16-18° for A- and C-screws and 30° for the B-screw - allowing a greater range of posterior swing than the medial side.

Indexed as

Bone screwsDistal femoral osteotomyOsteotomyPlate fixationTomographyX-Ray computed

Identifiers

PMID41603462
PMCPMC12849697

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.