ArticleFrontiers in bioengineering and biotechnology2025
Finite element analysis and in vitro simulation experiments on ophthalmic trocar needles.
Article in Frontiers in bioengineering and biotechnology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction: Ophthalmic trocar systems are commonly used to establish a passage into the vitreous cavity in complex ophthalmic surgeries, and optimizing the design of trocar needles may potentially reduce surgical trauma and the risk of complications. Methods: Study combined Results: In penetration force tests, the penetration force of the 25G needles was 14.62% lower than that of the 23G group (P < 0.001), cause a smaller needle diameter increased penetration efficiency. Further findings showed that the 23G needles with a smaller needle tip surface and longer bevel had a significantly lower penetration force than the 25G needle (P < 0.01), which indicated that bevel length along with the tip surface play vital roles in penetration efficiency. The penetration force measurement results showed that an optimal range of tip quadrilateral surface areas led to better tip strength performance. Finite element analysis found that the initial stress concentration was primarily determined by the geometry of the needle tip, while the diameter and surface properties of the needle shaft influence the stress distribution throughout the penetrating process, which interpreted the data Discussion: This study proved that a multi-stage tapering needle with apex truncated and a reasonable bevel length enhanced the strength of the needle tip while improving cutting efficiency, and provided scientific basis for designing ophthalmic trocar systems. Clinical studies could be taken in the further to meet the ophthalmic surgery developing toward greater precision and minimal invasiveness.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.