Evidence map›Paper›PMID 41600528›Full record

ArticleSensors (Basel, Switzerland)2026

Wearable ECG-PPG Deep Learning Model for Cardiac Index-Based Noninvasive Cardiac Output Estimation in Cardiac Surgery Patients.

Minwoo Kim, Min Dong Sung, Jimyeoung Jung, Sung Pil Cho, Junghwan Park, Sarah Soh, Hyun Chel Joo, Kyung Soo Chung

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Minwoo KimMEZOO Co., Ltd., 200, Gieopdosi-ro, Jijeong-myeon, Wonju-si 26354, Republic of Korea.ORCID 0000-0001-8133-8449
Min Dong SungDivision of Pulmonology and Critical Care Medicine, Department of Internal Medicine, Institute for Innovation in Digital Healthcare, Yonsei University College of Medicine, Seoul 03722, Republic of Korea.ORCID 0000-0002-5217-8877
Jimyeoung JungMEZOO Co., Ltd., 200, Gieopdosi-ro, Jijeong-myeon, Wonju-si 26354, Republic of Korea.
Sung Pil ChoMEZOO Co., Ltd., 200, Gieopdosi-ro, Jijeong-myeon, Wonju-si 26354, Republic of Korea.ORCID 0009-0003-8914-7091
Junghwan ParkMEZOO Co., Ltd., 200, Gieopdosi-ro, Jijeong-myeon, Wonju-si 26354, Republic of Korea.ORCID 0000-0002-7433-0980
Sarah SohAnaesthesia and Pain Research Institute, Department of Anaesthesiology and Pain Medicine, Yonsei University College of Medicine, Seoul 03722, Republic of Korea.ORCID 0000-0001-5022-4617
Hyun Chel JooDivision of Cardiovascular Surgery, Department of Cardiovascular and Thoracic Surgery, Yonsei University College of Medicine, Seoul 03722, Republic of Korea.ORCID 0000-0002-6842-2942
Kyung Soo ChungDivision of Pulmonology and Critical Care Medicine, Department of Internal Medicine, Institute for Innovation in Digital Healthcare, Yonsei University College of Medicine, Seoul 03722, Republic of Korea.ORCID 0000-0003-1604-8730

Funding

the Ministry of Health and Welfare, Republic of Korea RS-2023-00266056the Ministry of SMEs and Startups, Republic of Korea RS-2023-00303821
6 · The paper itself

Abstract

Accurate cardiac output (CO) measurement is vital for hemodynamic management; however, it usually requires invasive monitoring, which limits its continuous and out-of-hospital use. Wearable sensors integrated with deep learning offer a noninvasive alternative. This study developed and validated a lightweight deep learning model using wearable electrocardiography (ECG) and photoplethysmography (PPG) signals to predict CO and examined whether cardiac index-based normalization (Cardiac Index (CI) = CO/body surface area) improves performance. Twenty-seven patients who underwent cardiac surgery and had pulmonary artery catheters were prospectively enrolled. Single-lead ECG (HiCardi+ chest patch) and finger PPG (WristOx2 3150) were recorded simultaneously and processed through an ECG-PPG fusion network with cross-modal interaction. Three models were trained as follows: (1) CI prediction, (2) direct CO prediction, and (3) indirect CO prediction. The total number of CO = predicted CI × body surface area. Reference values were derived from thermodilution. The CI model achieved the best performance, and the indirect CO model showed significant reductions in error/agreement metrics (MAE/RMSE/bias;

Indexed as

Cardiac OutputCardiac Surgical ProceduresDeep LearningElectrocardiographyPhotoplethysmographyWearable Electronic DevicesAgedFemaleHumansMaleMiddle AgedMonitoring, Physiologiccardiac indexcardiac outputcardiac surgerydeep learningelectrocardiography (ECG)hemodynamic monitoringmultimodal fusionphotoplethysmography (PPG)wearable sensors

Identifiers

PMID41600528
PMCPMC12845561

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.