Evidence map›Paper›PMID 41600507›Full record

ArticleSensors (Basel, Switzerland)2026

Enhanced Gas Classification in Electronic Nose Systems Using an SMOTE-Augmented Machine Learning Framework.

Minqiang Li, Chenxi Wu, Zhiyang Wang, Zhijian Wu, Wei Huang, Junru Chen, Kaibo Yu, Ting Wen, Hongbo Yin, Zhuqing Wang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Minqiang LiSchool of Electronic Engineering, Chengdu Technological University, Chengdu 610031, China.
Chenxi WuSchool of Mechanical Engineering, Sichuan University, Chengdu 610065, China.
Zhiyang WangSchool of Pittsburgh Institute, Sichuan University, Chengdu 610065, China.
Zhijian WuSchool of Mechanical Engineering, Sichuan University, Chengdu 610065, China.
Wei HuangSchool of Mechanical Engineering, Sichuan University, Chengdu 610065, China.
Junru ChenSchool of Pittsburgh Institute, Sichuan University, Chengdu 610065, China.
Kaibo YuSchool of Mechanical Engineering, Sichuan University, Chengdu 610065, China.
Ting WenSchool of Mechanical Engineering, Sichuan University, Chengdu 610065, China.
Hongbo YinDepartment of ophthalmology, West China Hospital, Sichuan University, Chengdu 610041, China.
Zhuqing WangSchool of Mechanical Engineering, Sichuan University, Chengdu 610065, China.ORCID 0000-0002-7513-5773

Funding

Chengdu Eastern New District Technology Innovation and Research and Development Project No.2024-DBXQ-KJYF006International Cooperation Project of Sichuan Province No.2024YFHZ0278National Key Research and Development Program of China No.2024YFE0114700Sichuan Science and Technology Program No.2025ZNSFSC0485
6 · The paper itself

Abstract

Electronic nose systems are widely used in environmental monitoring and other related fields. In recent years, systems based on gas sensor arrays have attracted considerable attention. However, relying solely on improvements in gas-sensitive materials has struggled to break through the bottleneck in recognition accuracy. To address this challenge, this study designs and validates an integrated machine learning framework for enhanced gas identification in electronic nose systems. Specifically, (1) a Butterworth low-pass filter is combined with principal component analysis (PCA) to suppress sensor noise; (2) the synthetic minority over-sampling technique (SMOTE) is utilized for training set data augmentation to further enhance the classification accuracy of the support vector machine (SVM); and (3) the relationship between single-component and mixed-gas responses is analyzed to construct an artificial neural network (ANN) regression model. Experimental results demonstrate that the SMOTE-augmented, PCA-optimized SVM model achieves a recognition accuracy of 0.93 ± 0.08 for most target gases, representing improvements of 19% and 7% over decision tree and ANN classifiers, respectively, and that the ANN regression model attains a correlation coefficient of 99.55% between predicted and measured values in mixed-gas experiments. Overall, the construction and optimization of this system demonstrate significant practical value for intelligent gas identification and the development of advanced e-nose devices.

Indexed as

electronic nose systemfeature extractiongas sensor arraymachine learningSMOTE

Identifiers

PMID41600507
PMCPMC12845625

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.