ArticleSensors (Basel, Switzerland)2026
LC Resonant-Based Method for Permeability Interference Suppression in Magnetized Pipeline Eddy Current Testing.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In the eddy current testing (ECT) of magnetized ferromagnetic pipelines, permeability perturbations near defects cause magnetic distortion that primarily modulates the imaginary part of the ECT sensor's impedance, leading to confusion between inner and outer wall defect signals. To address this interference, this study thoroughly analyzes the modulation mechanism of permeability changes on impedance and investigates the feasibility of detecting solely the real part to enhance discrimination reliability. This understanding leads to the proposal of a solution employing an LC resonant circuit, capitalizing on its characteristic of zero imaginary part impedance at the resonant frequency, to effectively suppress the permeability-related signal interference. Experimental results demonstrate the effectiveness of the proposed approach: the magnetization response test confirms the insensitivity of the LC sensor to permeability perturbations, and the defect discrimination experiment shows that the sensor achieves a standard deviation ratio of 2.25 and a peak-to-peak ratio of 4.42 between inner and outer wall defect signals. The findings indicate that the LC resonant sensor can reliably distinguish between inner and outer wall defects through simple amplitude thresholding, thereby improving the reliability of inspections for magnetized pipelines in industrial applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.