ArticleSensors (Basel, Switzerland)2026
A Dual-Purpose Biomedical Measurement System for the Evaluation of Real-Time Correlations Between Blood Pressure and Breathing Parameters.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This paper proposes a low-cost measurement system that can be used to perform simultaneous blood pressure (BP) and breathing (BR) measurements. Regarding BP measurements, the main parameters that are accessed include systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure blood pressure (MAP), and heartbeat rate (HR). Concerning BR measurements, the main parameters that are accessed include the inspiration period and amplitude (IPA), the expiration period and amplitude (EPA), and the breathing rate (BR), as well as the statistical and standard deviation of all these parameters. The dual measurement capability of the proposed measurement system is very important since blood pressure and breathing parameters are not statistically independent and it is possible to obtain additional and valuable clinical information from the information provided by both biomedical variables when measured simultaneously. The analysis of the correlation between these variables is particularly important after performing intensive physical exercises, since it enables cardiac rehabilitation assessment, pre-surgical risk evaluation, detection of silent ischemia, and monitoring of chronic diseases recovery, among others. Regarding the performance evaluation of the proposed biomedical device, a prototype of the measurement system was developed, tested, and calibrated. Several experimental tests were carried out to evaluate the performance of the proposed measurement system and to obtain the correlation coefficients between different blood pressure and breathing parameters. The tests were based on a statistically significant number of measurements that were performed with a population that integrated twenty students in two groups with different habits of physical exercise practice but subjected to a set of common physical exercises, with graduated intensity levels.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.