Evidence map›Paper›PMID 41600196›Full record

ArticleSensors (Basel, Switzerland)2026

A Fiber Optic Sensor Using a Molecularly Imprinted Chitosan Membrane Coating on a Fiber Surface as a Transducer for Discriminating 4-Nitrophenol from Its Positional Isomers.

Myra Arana, Shiquan Tao

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Myra AranaDepartment of Chemistry and Physics, West Texas A&M University, WTAMU Box 60732, Canyon, TX 79016, USA.
Shiquan TaoDepartment of Chemistry and Physics, West Texas A&M University, WTAMU Box 60732, Canyon, TX 79016, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

An optical fiber chemical sensor using a molecularly imprinted chitosan membrane coated on the surface of a bent optical fiber probe was developed for selectively analyzing 4-nitrophenol (4-NP) in water samples. When the sensor probe is exposed to a water sample, the chitosan MIP membrane extracts/concentrates 4-NP from the water sample into the membrane. The 4-NP extracted into the membrane was detected by passing a light beam through the optical fiber and the interaction of the 4-NP in the membrane with an evanescent wave of light guided through the optical fiber was detected as a sensing signal. This sensor detects the intrinsic optical absorption signal of 4-NP itself as a sensing signal. No chemical reagent was needed in analyzing this compound in a sample. The sensor is reversible, can be used for continuous monitoring of 4-NP in a sample, and has a quick response with a response time of 5 min. The sensor has high sensitivity and selectivity because the MIP membrane selectively concentrates 4-NP by 1.4 × 10

Indexed as

4-nitrophenolbent optical fiber probemolecularly imprinted polymeroptical fiber chemical sensorsolid phase microextraction

Identifiers

PMID41600196
PMCPMC12845851

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.