Evidence map›Paper›PMID 41599560›Full record

ArticlePolymers2026

Experimental and Numerical Assessment of Fiber Orientation Effects in Biaxial Glass/Vinyl Ester Laminates.

Sultan Ullah, Arvydas Palevicius, Almontas Vilutis, Raul Fangueiro, Giedrius Janusas

Abstract read
In one paragraph

Article in Polymers, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Sultan UllahDepartment of Mechanical Engineering, Faculty of Mechanical Engineering and Design, Kaunas University of Technology, Studentų 56, LT-51424 Kaunas, Lithuania.ORCID 0000-0003-1233-1926
Arvydas PaleviciusDepartment of Mechanical Engineering, Faculty of Mechanical Engineering and Design, Kaunas University of Technology, Studentų 56, LT-51424 Kaunas, Lithuania.ORCID 0000-0003-1226-062X
Almontas VilutisDepartment of Engineering, UAB Poliplastas, Geliu St. 97, LT-53330 Kaunas, Lithuania.
Raul FangueiroFibrenamics, Institute of Innovation on Fibre-Based Materials and Composites, University of Minho, 4800-058 Guimarães, Portugal.
Giedrius JanusasDepartment of Mechanical Engineering, Faculty of Mechanical Engineering and Design, Kaunas University of Technology, Studentų 56, LT-51424 Kaunas, Lithuania.ORCID 0000-0002-1055-2568

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study analyzes the mechanical behavior of a quasi-isotropic biaxial glass fiber-vinyl ester composite in a multiaxial stress condition and the effect of the orientation of the fibers. A ply structure was created through the process of vacuum infusion using six layers of biaxial fabric that were oriented to 15°. Tensile samples were isolated at 0, 15, 30, 45 and 90 degrees relative to the warp direction. It was found that strength and stiffness strongly depend on orientation, with maximum tensile strengths of 157.2 MPa at 90° and 125 MPa at 0°, and minimum tensile strengths 59.6 MPa at 15°, showing fiber and shear failures, respectively. MAT_124 underwent finite element analysis in LS-DYNA, and the results were excellent, with a difference of less than 1.5%. Three-point bending and Charpy impact tests indicated that flexural properties were lower at 15° and 90°, whereas off-axis orientations were generally better at impact energy absorption, although at 45°, binding sites were few and far between. The results have important implications for the design of laminates subjected to complicated loads.

Indexed as

biaxial fabric compositeFEAmechanical propertiesstacking sequencethermosetVARTM

Identifiers

PMID41599560
PMCPMC12845792

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.