Evidence map›Paper›PMID 41599375›Full record

ArticleMolecules (Basel, Switzerland)2026

Genipin as an Effective Crosslinker for High-Performance and Flexible Direct-Printed Bioelectrodes.

Kornelia Bobrowska, Marcin Urbanowicz, Agnieszka Paziewska-Nowak, Marek Dawgul, Kamila Sadowska

Abstract read
In one paragraph

Article in Molecules (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kornelia BobrowskaNalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Ks. Trojdena 4 St., 02-109 Warsaw, Poland.ORCID 0009-0009-9073-2371
Marcin UrbanowiczNalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Ks. Trojdena 4 St., 02-109 Warsaw, Poland.ORCID 0000-0002-3853-6965
Agnieszka Paziewska-NowakNalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Ks. Trojdena 4 St., 02-109 Warsaw, Poland.ORCID 0000-0003-0883-3691
Marek DawgulNalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Ks. Trojdena 4 St., 02-109 Warsaw, Poland.ORCID 0000-0002-4578-4975
Kamila SadowskaNalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Ks. Trojdena 4 St., 02-109 Warsaw, Poland.ORCID 0000-0002-5271-8730

Funding

Nalecz Institute of Biocybernetics and Biomedical Engineering Polish Academy of Sciences FBW/2.7/2National Science Centre 2021/43/O/ST5/01925
6 · The paper itself

Abstract

The development of efficient bioelectrodes requires suitable fabrication strategies, starting with the electrode material, which affects the electron transfer between the biocatalyst and the electrode surface. Then, selection and adjustment of the enzyme immobilization conditions are essential to enhance the performance of the bioelectrodes for their desirable utility. In this study, we report the fabrication of a high-performance bioelectrode using a one-step crosslinking of FAD-dependent glucose dehydrogenase (FAD-GDH) and thionine acetate as a redox mediator, with genipin serving as a natural, biocompatible crosslinker. Electrodes were manufactured on flexible polyester substrates using a direct printing technique, enabling reproducible and low-cost production. Among the tested crosslinkers, genipin significantly enhanced the catalytic performance of bioelectrodes. Comparative studies on graphite, silver, and gold electrode materials identified graphite as the most suitable due to its extended electroactive surface area. The developed bioelectrodes applied to glucose biosensing demonstrated a linear amperometric response to glucose in the range of 0.02-2 mM and 0.048-30 mM, covering clinically relevant concentrations. The application of artificial sweat confirmed high detection accuracy. These findings highlight the potential integration of genipin-based enzyme-mediator networks for future non-invasive sweat glucose monitoring platforms.

Indexed as

Biosensing TechniquesCross-Linking ReagentsIridoidsElectrochemical TechniquesElectrodesEnzymes, ImmobilizedGlucoseGlucose 1-DehydrogenaseGraphiteOxidation-ReductionPhenothiazinesCross-Linking ReagentsEnzymes, ImmobilizedgenipinGlucoseGlucose 1-DehydrogenaseGraphiteIridoidsPhenothiazinesthioninedirect printingFAD-dependent glucose dehydrogenasegenipinmediated electron transfer

Identifiers

PMID41599375
PMCPMC12843758

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.