ArticleMicromachines2026
High-Resolution Snapshot Multispectral Imaging System for Hazardous Gas Classification and Dispersion Quantification.
Article in Micromachines, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
Real-time monitoring of hazardous gas emissions in open environments remains a critical challenge. Conventional spectrometers and filter wheel systems acquire spectral and spatial information sequentially, which limits their ability to capture multiple gas species and dynamic dispersion patterns rapidly. A High-Resolution Snapshot Multispectral Imaging System (HRSMIS) is proposed to integrate high spatial fidelity with multispectral capability for near real-time plume visualization, gas species identification, and concentration retrieval. Operating across the 7-14 μm spectral range, the system employs a dual-path optical configuration in which a high-resolution imaging path and a multispectral snapshot path share a common telescope, allowing for the simultaneous acquisition of fine two-dimensional spatial morphology and comprehensive spectral fingerprint information. Within the multispectral path, two 5×5 microlens arrays (MLAs) combined with a corresponding narrowband filter array generate 25 distinct spectral channels, allowing concurrent detection of up to 25 gas species in a single snapshot. The high-resolution imaging path provides detailed spatial information, facilitating spatio-spectral super-resolution fusion for multispectral data without complex image registration. The HRSMIS demonstrates modulation transfer function (MTF) values of at least 0.40 in the high-resolution channel and 0.29 in the multispectral channel. Monte Carlo tolerance analysis confirms imaging stability, enabling the real-time visualization of gas plumes and the accurate quantification of dispersion dynamics and temporal concentration variations.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.