Evidence map›Paper›PMID 41597858›Full record

ArticleMicromachines2026

Strain and Electromyography Dual-Mode Stretchable Sensor for Real-Time Monitoring of Joint Movement.

Hanfei Li, Xiaomeng Zhou, Shouwei Yue, Qiong Tian, Qingsong Li, Jianhong Gong, Yong Yang, Fei Han, Hui Wei, Zhiyuan Liu and 1 more

Abstract read
In one paragraph

Article in Micromachines, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Hanfei LiSchool of Airspace Science and Engineering, Shandong University, Weihai 264209, China.
Xiaomeng ZhouNeural Engineering Centre, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.ORCID 0000-0002-1103-7146
Shouwei YueDepartment of Physical Medicine & Rehabilitation, Qilu Hospital, Shandong University, Jinan 250012, China.
Qiong TianNeural Engineering Centre, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
Qingsong LiNeural Engineering Centre, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
Jianhong GongSchool of Airspace Science and Engineering, Shandong University, Weihai 264209, China.
Yong YangHand Surgery Department, Beijing Jishuitan Hospital, Capital Medical University, Beijing 100035, China.
Fei HanNeural Engineering Centre, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
Hui WeiDepartment of Physical Medicine & Rehabilitation, Qilu Hospital, Shandong University, Jinan 250012, China.
Zhiyuan LiuNeural Engineering Centre, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.ORCID 0000-0001-9231-8195
Yang ZhaoNeural Engineering Centre, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.

Funding

International Partnership Program of the Chinese Academy of Sciences 321GJHZ2024176MINational Key R&D Program of China 2023YFC2414500, 2023YFC2414501National Natural Science Foundation of China 62101544, 62201558, 62101545, and 62201559Shenzhen Science and Technology Program KQTD20210811090217009, JCYJ20230807140606012Strategic Priority Research Program of the Chinese Academy of Sciences XDB0930000
6 · The paper itself

Abstract

Flexible sensors have emerged as critical interfaces for information exchange between soft biological tissues and machines. Here, we present a dual-mode stretchable sensor system capable of synchronous strain and electromyography (EMG) signal detection, integrated with wireless WIFI transmission for real-time joint movement monitoring. The system consists of two key components: (1) A multi-channel gel electrode array for high-fidelity EMG signal acquisition from target muscle groups, and (2) a novel capacitive strain sensor made of stretchable micro-cracked gold film based on Styrene Ethylene Butylene Styrene (SEBS) that exhibits exceptional performance, including >80% stretchability, >4000-cycle durability, and fast response time (<100 ms). The strain sensor demonstrates position-independent measurement accuracy, enabling robust joint angle detection regardless of placement variations. Through synchronized mechanical deformation and electrophysiological monitoring, this platform provides comprehensive movement quantification, with data visualization interfaces compatible with mobile and desktop applications. The proposed technology establishes a generalizable framework for multimodal biosensing in human motion analysis, robotics, and human-machine interaction systems.

Indexed as

capacitive strain sensordual-modeelectromyography monitoringnanogold filmSEBSstretchable electronics

Identifiers

PMID41597858
PMCPMC12843643

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.