ArticleMicromachines2025
Flexible Three-Dimensional Stress Sensor for Embedded Monitoring of Solid Rocket Propellant.
Article in Micromachines, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Embedded Wireless Flexible Sensor for Monitoring Interface Stress of Solid Rocket Motor.Sensors (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Solid rocket motors (SRMs) play a pivotal role in space exploration owing to their reliability and high thrust-to-weight ratios. SRM propellant health monitoring is in critical demand owing to the complex operational scenarios throughout the entire life cycle of SRMs. To achieve in situ detection of three-dimensional stress, this study introduces a novel flexible three-dimensional stress sensor (FSS). First, a liquid metal pressure-sensing element with a variable cross-section was designed and numerically modeled. The performance of the FSS under different loading conditions was analyzed using finite element modeling. The sensing element prototype was fabricated using mold casting and liquid metal injection methods. The fabricated sensing-element prototype with an area ratio of 1:5 exhibited a sensitivity coefficient of 1.5%/kPa at a pressure of 300 kPa, a maximum hysteresis error of 3.98%, and a stability error of 0.17%. Finally, the FSS was developed by integrating multiple pressure-sensing elements and encapsulating the force-concentrating layers. The fabricated FSS prototype was characterized using simulated propellant experiments. Via comparison with the simulation results, the FSS was found to detect multiaxial stress differences when embedded within a propellant.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.