ArticleMicroorganisms2025

Evaluation of Commercial Immunoassays for Rubella Virus IgG Detection in Low-Antibody Sera Using a Recombinant Immunoblot as a Reference Method.

Carmen Ortega, Antonio Sampedro-Padilla, Pablo Mazuelas, Jose Serrano, Ana Abreu, Juan Antonio Reguera, Javier Rodríguez-Granger, Fernando Cobo, Juan Francisco Gutiérrez-Bautista, Antonio Sampedro

Abstract read
In one paragraph

Article in Microorganisms, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Carmen OrtegaServicio de Microbiología, Virgen de las Nieves University Hospital, 18014 Granada, Spain.
Antonio Sampedro-PadillaZaidín Sur Health Center, Andalusian Health Service, Granada Metropolitan District, 18007 Granada, Spain.
Pablo MazuelasServicio de Microbiología, Virgen de la Victoria University Hospital, 29010 Malaga, Spain.
Jose SerranoServicio de Microbiología, Virgen de las Nieves University Hospital, 18014 Granada, Spain.ORCID 0009-0003-7518-4027
Ana AbreuServicio de Microbiología, Virgen de las Nieves University Hospital, 18014 Granada, Spain.
Juan Antonio RegueraServicio de Microbiología, Virgen de las Nieves University Hospital, 18014 Granada, Spain.ORCID 0000-0003-1970-8562
Javier Rodríguez-GrangerServicio de Microbiología, Virgen de las Nieves University Hospital, 18014 Granada, Spain.
Fernando CoboServicio de Microbiología, Virgen de las Nieves University Hospital, 18014 Granada, Spain.ORCID 0000-0002-9203-9628
Juan Francisco Gutiérrez-BautistaInstituto de Investigación Biosanitaria de Granada (ibs.GRANADA), 18012 Granada, Spain.ORCID 0000-0003-1374-0756
Antonio SampedroServicio de Microbiología, Virgen de las Nieves University Hospital, 18014 Granada, Spain.ORCID 0000-0002-8773-4474

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Rubella virus (RV) IgG quantification is essential for verifying immunity, particularly in prenatal care. However, substantial variability exists among commercial immunoassays, especially when testing low-antibody sera. In this study, we evaluated five commercial assays-four chemiluminescent immunoassays (CLIAs) and one Enzyme-linked Immunosorbent Assay (ELISA)-using a recombinant immunoblot (IB) as the reference method. A panel of 137 serum samples with low or undetectable IgG levels was analyzed. Sensitivity ranged from 19.6% to 70.1%, while specificity exceeded 94%. Only 18.6% of immunoblot-positive samples tested positive across all assays. Marked quantitative differences were observed, with the Atellica assay yielding the highest titers and Alinity the lowest. Reclassifying equivocal results as positive improved concordance without compromising specificity. These findings suggest that current cut-off values, derived from post-infection sera, may be inadequate for vaccinated populations. A single universal threshold may lead to misclassification and underestimation of immunity. Harmonization of assay calibrations, antigenic targets, and interpretation criteria is urgently needed to ensure reliable rubella immunity assessments in clinical and public health settings.

Indexed as

immunoassay variabilitylow-titer vaccinated populationsrubella IgGrubella immunity assessmentserological assay harmonization