Evidence map›Paper›PMID 41595981›Full record

ArticleBioengineering (Basel, Switzerland)2025

A Deep Learning Model That Combines ResNet and Transformer Architectures for Real-Time Blood Glucose Measurement Using PPG Signals.

Ting-Hong Chen, Lei Wang, Qian-Xun Hong, Meng-Ting Wu

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ting-Hong ChenDepartment of Electrical Engineering, Feng-Chia University, Taichung 40724, Taiwan.ORCID 0009-0008-5745-2581
Lei WangDepartment of Electrical Engineering, Feng-Chia University, Taichung 40724, Taiwan.ORCID 0009-0009-6508-9548
Qian-Xun HongDepartment of Electrical Engineering, Feng-Chia University, Taichung 40724, Taiwan.ORCID 0009-0005-7844-7907
Meng-Ting WuDivision of Neurosurgery, Department of Surgery, Cheng-Hsin General Hospital, Taipei 11220, Taiwan.ORCID 0000-0002-4655-6907

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Recent advances in wearable devices and physiological signal monitoring technologies have motivated research into non-invasive glucose estimation for diabetes management. However, the existing studies are often limited by sample constraints, in terms of relatively small numbers of subjects, and few address personalized differences. Physiological signals vary considerably for different individuals, affecting the reliability of accuracy measurements, and training data and test data are both used from the same subjects, which makes the test result more affirmative than the truth. This study aims to compare the two scenarios mentioned above, regardless of whether the testing/training involves the same individual, in order to determine whether the proposed training method has better generalization ability. The publicly available MIMIC-III dataset, which contains 700,000 data points for 10,000 subjects, is used to create a more generalized model. The model architecture uses a ResNet CNN + Transformer block, and data quality is graded during preprocessing to select signals with less interference for training to increase data quality. This preprocessing method allows the model to extract useful features without being adversely affected by noise and anomalous data that decreases performance; therefore, the model's training results and generalization capability are increased. This study creates a model to predict blood glucose values from 70 to 250 for 180 classes, using mean absolute relative difference (MARD) as the evaluation metric and a Clarke error grid (CEG) to determine a reasonable error tolerance. For personalized cases (specific individual data during model training), the MARD is 11.69%, and the optimal Zone A (representing no clinical risk) in the Clarke error grid is 82.7%. Non-personalized cases (test subjects not included in the model training samples) using 60,000 unseen data yields MARD = 15.16%, and the optimal Zone A in the Clarke error grid is 75.4%. Across multiple testing runs, the proportion of predictions falling within Clarke error grid zones A and B consistently approached 100%. The small performance difference suggests that the proposed method has the potential to improve subject-independent estimation; however, further validation in broader populations is required. Therefore, the primary objective of this study is to improve subject-independent, non-personalized PPG-based glucose estimation and reduce the performance gap between personalized and non-personalized measurements.

Indexed as

blood glucose predictionClarke error grid (CEG)deep learningMIMIC-III datasetnon-invasive glucose monitoringphotoplethysmography (PPG)PhysioNetResNet–Transformer hybrid modelSignal Quality Index (SQI)

Identifiers

PMID41595981
PMCPMC12838076

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.