Evidence map›Paper›PMID 41591963›Full record

ArticleFolia phoniatrica et logopaedica : official organ of the International Association of Logopedics and Phoniatrics (IALP)2026

Accuracy of Balloons and Handheld Spirometers as Low-Cost Tools for Measuring Vital Capacity and Air Volume: A Laboratory-Based Validation Study.

James A Curtis, Mel Grasso, Brandon Jagdhar

Abstract read
In one paragraph

Article in Folia phoniatrica et logopaedica : official organ of the International Association of Logopedics and Phoniatrics (IALP), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Development and Initial Validation of Phonation Quotient for Connected Speech: A Low-Cost, Indirect Aerodynamic Measure of Phonatory Airflow.Folia phoniatrica et logopaedica : official organ of the International Association of Logopedics and Phoniatrics (IALP) · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

James A CurtisAerodigestive Innovations Research Lab (AIR), Department of Otolaryngology-Head & Neck Surgery, Weill Cornell Medical College of Cornell University, Ithaca, New York, USA, yrj9003@med.cornell.edu.
Mel GrassoAerodigestive Innovations Research Lab (AIR), Department of Otolaryngology-Head & Neck Surgery, Weill Cornell Medical College of Cornell University, Ithaca, New York, USA.
Brandon JagdharAerodigestive Innovations Research Lab (AIR), Department of Otolaryngology-Head & Neck Surgery, Weill Cornell Medical College of Cornell University, Ithaca, New York, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionVital capacity and air volume are key physiological substrates important for voice, speech, cough, and swallowing. The current gold standard equipment to assess vital capacity and air volume is a pneumotachograph. The aim of this study was to characterize the validity of four low-cost, clinically accessible tools as potential alternative methods to accurately assess vital capacity and air volume.

methodsThis laboratory-based study examined the accuracy of four low-cost tools to assess vital capacity and air volume: two balloon-based circumference methods (<USD 1), one analogue spirometer (∼USD 100), and one consumer-grade digital spirometer (∼USD 150). In experiment 1, known volumes of air (ground truth) were injected into each low-cost tool using a 3-L calibration syringe. In experiment 2, the same tools were tested against gold standard pneumotachography equipment. Agreement was assessed using descriptive statistics, Lin's concordance correlation coefficient (ρ

resultsAll four tools showed substantial agreement with the ground truth and gold standard measurements. Median absolute differences ranged from 0.07 to 0.29 L across tools. The digital spirometer demonstrated the highest agreement, with ρ

conclusionThe findings support the use of balloon-based circumference techniques, analogue spirometry, and digital spirometry as low-cost alternatives for measuring vital capacity. Each tool demonstrated predictable error patterns that could be corrected to yield highly accurate estimates. These results may expand access to vital capacity measurement in outpatient, home health, and resource-limited settings.

Indexed as

AssessmentBalloonFeasibilityValidityVital capacity

Identifiers

PMID41591963
PMCPMC12962714

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.