Fundamental performance and clinical usefulness of a new AEC-equipped flat panel detector for dose optimization.

Sho Maruyama, Hiroki Saitou, Nao Koyama

Abstract read
PubMed Publisher
In one paragraph

Article in Physical and engineering sciences in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Sho MaruyamaDepartment of Radiological Technology, Gunma Prefectural College of Health Sciences, Maebashi, Gunma, 323-1, Kamioki371-0052, Japan. maruyama@gchs.ac.jp.ORCID http://orcid.org/0000-0003-0140-5993
Hiroki SaitouDepartment of Medical Technology, Teikyo University, Itabashi, Tokyo, Japan.
Nao KoyamaDepartment of Radiology, Teikyo University Hospital, Itabashi, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The demand for bedside radiography is increasing due to critical clinical needs, including infection control and the limited mobility of severely ill patients. However, radiation dose adjustment in these settings remains heavily reliant on the expertise and experience of radiographers. To address this issue, a novel flat panel detector (FPD) integrated with an automatic exposure control (AEC) system has been developed. This study aims to experimentally evaluate the fundamental performance of this system and clarify its clinical utility, including its potential limitations. The dependency of the AEC performance on object thickness and tube voltage was investigated using acrylic phantoms. To simulate clinical scenarios, the AEC response was examined using a chest phantom. Additionally, the effects of source-to-image distance and oblique X-ray incidence on the AEC performance were also evaluated using a quality-control test device. Our results elucidated the behavior of the exposure index (EI) and image quality under varying tube voltage and object thickness. In clinical conditions, the introduction of the AEC system significantly reduced EI, confirming its potential for effective dose management. Multiple factors were identified that influence both the AEC response and image quality, such as sensor positioning, imaging distance, and beam angle. These findings demonstrate that the AEC-equipped FPD system maintains consistent image quality while effectively reducing the radiation dose under various simulated imaging conditions. Our results also underscore the importance of accounting for environmental factors that affect dose control and image characteristics, highlighting the need for practical adjustment in routine clinical operation.

Indexed as

Radiation DosageHumansPhantoms, ImagingAuto exposure controlBedside radiographyDiagnostic reference levelsFlat panel detectorOptimization

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.