Evidence map›Paper›PMID 41591618›Full record

ArticleThe international journal of cardiovascular imaging2026

Automatic detection and measurement system for aortic aneurysms using deep learning-based artificial intelligence.

Jumpei Fujiwara, Makoto Orii, Kohei Oyamada, Kenta Araki, Masahiko Ogura, Tomoyasu Ito, Daria Bunu, Ryoto Ando, Takashi Okada, Kunihiro Yoshioka

Abstract readValidation Study
PubMed Publisher
In one paragraph

Article in The international journal of cardiovascular imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Jumpei FujiwaraDepartment of Radiology, Iwate Medical University, Yahaba, Morioka, Japan.
Makoto OriiDepartment of Radiology, Iwate Medical University, Yahaba, Morioka, Japan. kori931@gmail.com.
Kohei OyamadaTechnology and Innovation General HQs, NTT DATA Group Corporation, Toyosu, Tokyo, Japan.
Kenta ArakiTechnology and Innovation General HQs, NTT DATA Group Corporation, Toyosu, Tokyo, Japan.
Masahiko OguraTechnology and Innovation General HQs, NTT DATA Group Corporation, Toyosu, Tokyo, Japan.
Tomoyasu ItoTechnology and Innovation General HQs, NTT DATA Group Corporation, Toyosu, Tokyo, Japan.
Daria BunuTechnology and Innovation General HQs, NTT DATA Group Corporation, Toyosu, Tokyo, Japan.
Ryoto AndoTechnology and Innovation General HQs, NTT DATA Group Corporation, Toyosu, Tokyo, Japan.
Takashi OkadaTechnology and Innovation General HQs, NTT DATA Group Corporation, Toyosu, Tokyo, Japan.
Kunihiro YoshiokaDepartment of Radiology, Iwate Medical University, Yahaba, Morioka, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study evaluated the performance of a deep learning-based artificial intelligence (DLAI) system for detecting fusiform aortic aneurysms and measuring the diameters of the entire aorta on non-contrast CT images.We retrospectively collected 160 non-contrast CT images (130 males, 71.8 ± 9.2 years) to evaluate aortic aneurysms and used them as training data. To evaluate the accuracy of the DLAI system for the automatic detection and measurement of aortic aneurysms, another 190 non-contrast CT images (153 males, 70.7 ± 10.3 years) were collected and used as validation data. First, the accuracy of DLAI results was calculated by referring to the radiology reports. An expert radiologist read the test data again and calculated the final accuracy by referring to the DLAI predictions.Dice scores for aortic segmentation were 0.90, 0.94, 0.93, and 0.84 for the entire aorta, thoracic aorta, abdominal aorta, and iliac artery, respectively. The sensitivity, positive predictive value, and F-measure of the DLAI system for detecting aortic aneurysms were 0.81, 0.83, and 0.82, respectively. Eleven (4.4%) aneurysms were newly identified after the radiologist's second reading based on DLAI predictions. The final accuracy of the DLAI detection increased to 0.83, 0.87, and 0.85 for sensitivity, positive predictive value, and F-measure, respectively. The size error in the measurement of aortic aneurysms between the DLAI system and radiology reports was 0.86 ± 2.72 mm, with a strong correlation (ICCs = 0.97).Our DLAI system was highly accurate in detecting aneurysms and measuring the diameters of the entire aorta on non-contrast CT images.

Indexed as

Aortic Aneurysm, AbdominalAortic Aneurysm, ThoracicAortographyComputed Tomography AngiographyDeep LearningRadiographic Image Interpretation, Computer-AssistedAgedAged, 80 and overAutomationDetection AlgorithmsFemaleHumansIntelligent SystemsMaleMiddle AgedPredictive Value of TestsAortic aneurysmDeep learning-based artificial intelligenceNon-contrast computed tomography

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.