Evidence map›Paper›PMID 41591485›Full record

ArticleSkeletal radiology2026

Optimizing knee MRI near orthopedic hardware using a 3D-printed anatomical phantom.

William Tracqui, Habeeb Yusuff, Lucile Hausser, Alice Tournayre, Guillaume Bierry, Jean-Philippe Dillenseger, Thibault Willaume

Abstract read
PubMed Publisher
In one paragraph

Article in Skeletal radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

William TracquiDepartment of Radiology, University Hospital of Strasbourg, 1 Avenue Moliere, 67098, Strasbourg, France.
Habeeb YusuffUMR 7357, ICube, CNRS, University of Strasbourg, 67000, Strasbourg, France.
Lucile HausserDepartment of Radiology, University Hospital of Strasbourg, 1 Avenue Moliere, 67098, Strasbourg, France.
Alice TournayreDepartment of Radiology, University Hospital of Strasbourg, 1 Avenue Moliere, 67098, Strasbourg, France.
Guillaume BierryDepartment of Radiology, University Hospital of Strasbourg, 1 Avenue Moliere, 67098, Strasbourg, France.
Jean-Philippe DillensegerDepartment of Radiology, University Hospital of Strasbourg, 1 Avenue Moliere, 67098, Strasbourg, France.
Thibault WillaumeDepartment of Radiology, University Hospital of Strasbourg, 1 Avenue Moliere, 67098, Strasbourg, France. thibault.willaume@chru-strasbourg.fr.ORCID http://orcid.org/0000-0002-7646-9724

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo evaluate whether a dedicated, anatomically realistic knee phantom with orthopedic implants can be used to optimize clinical MRI sequences under realistic metallic conditions and to assess whether phantom-optimized sequences improve image quality compared with routine protocols. MATERIALS AND

methodsA 3D-printed knee phantom integrating a titanium screw and a stainless-steel fixation plate was developed. Phantom imaging was performed on a clinical 1.5 T MRI system. In this exploratory proof-of-concept study, T1w and STIR sequences were iteratively optimized using the phantom and compared with vendor-default and routine clinical protocols. The phantom-optimized sequences were subsequently applied in three asymptomatic volunteers with metallic knee implants and compared with routine sequences. Image quality was independently assessed by four blinded readers using a 5-point Likert scale across spatial resolution, artifact reduction, and overall image quality.

resultsPhantom-optimized sequences achieved significantly higher image quality scores compared with routine protocols. Improvements were consistent across all three predefined criteria: spatial resolution (mean increase +0.70 points, p < 0.001), artifact reduction (+0.65, p < 0.001), and overall image quality (+0.78, p < 0.001). These gains were observed for both T1-weighted and STIR acquisitions without extending acquisition times.

conclusionPhantom-guided optimization provides a reproducible, patient-independent framework for tuning MRI protocols near orthopedic hardware. Anatomically realistic phantoms represent a promising methodological tool for developing, testing, and standardizing MRI sequences under controlled and clinically relevant conditions.

Indexed as

Knee JointKnee ProsthesisMagnetic Resonance ImagingPhantoms, ImagingPrinting, Three-DimensionalArtifactsBone ScrewsHumansAnatomical phantomArtifactsMetallic implantsMRISequence optimizationSuper-phantoms

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.