ArticleNanomaterials (Basel, Switzerland)2026
Miniaturized High-Speed FBG Interrogator Based on a Photonic AWG Chip.
Article in Nanomaterials (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Lab-to-Field Transition in FBG Sensors: A Quantitative Assessment of Literature-Reported Deployment Maturity.Sensors (Basel, Switzerland) · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Although AWGs are widely used in FBG interrogation systems, conventional interrogators are often bulky and hard to deploy, limiting their use in complex field environments. Here, we developed an FBG interrogator based on a photonic AWG chip, comprising a photonic chip module, an optoelectronic detection and processing module, and an output interface module. The AWG chip measures only 280 µm × 150 µm, while the entire interrogator measures just 160 mm × 100 mm × 80 mm, achieving system miniaturization. Wavelength interrogation tests show that the FBG interrogator achieves a wavelength accuracy of 9.87 pm and a high-speed sampling rate of up to 10 kHz, enabling high-precision, real-time FBG demodulation under rapidly varying temperatures. Furthermore, the interrogator was subjected to engineering validation, with dynamic FBG wavelength demodulation experiments conducted under high-temperature shocks in a turbo-engine, verifying its reliability under extreme conditions and demonstrating its potential for broader engineering applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.